Quelle  powernv-op-panel.c   Sprache: C

 
// SPDX-License-Identifier: GPL-2.0-only
/*
 * OPAL Operator Panel Display Driver
 *
 * Copyright 2016, Suraj Jitindar Singh, IBM Corporation.
 */


#define pr_fmt(fmt) KBUILD_MODNAME ": " fmt

#include <linux/init.h>
#include <linux/module.h>
#include <linux/kernel.h>
#include <linux/fs.h>
#include <linux/device.h>
#include <linux/errno.h>
#include <linux/mutex.h>
#include <linux/of.h>
#include <linux/slab.h>
#include <linux/platform_device.h>
#include <linux/miscdevice.h>

#include <asm/opal.h>

/*
 * This driver creates a character device (/dev/op_panel) which exposes the
 * operator panel (character LCD display) on IBM Power Systems machines
 * with FSPs.
 * A character buffer written to the device will be displayed on the
 * operator panel.
 */


static DEFINE_MUTEX(oppanel_mutex);

static u32  num_lines, oppanel_size;
static oppanel_line_t *oppanel_lines;
static char  *oppanel_data;

static loff_t oppanel_llseek(struct file *filp, loff_t offset, int whence)
{
 return fixed_size_llseek(filp, offset, whence, oppanel_size);
}

static ssize_t oppanel_read(struct file *filp, char __user *userbuf, size_t len,
       loff_t *f_pos)
{
 return simple_read_from_buffer(userbuf, len, f_pos, oppanel_data,
   oppanel_size);
}

static int __op_panel_update_display(void)
{
 struct opal_msg msg;
 int rc, token;

 token = opal_async_get_token_interruptible();
 if (token < 0) {
  if (token != -ERESTARTSYS)
   pr_debug("Couldn't get OPAL async token [token=%d]\n",
    token);
  return token;
 }

 rc = opal_write_oppanel_async(token, oppanel_lines, num_lines);
 switch (rc) {
 case OPAL_ASYNC_COMPLETION:
  rc = opal_async_wait_response(token, &msg);
  if (rc) {
   pr_debug("Failed to wait for async response [rc=%d]\n",
    rc);
   break;
  }
  rc = opal_get_async_rc(msg);
  if (rc != OPAL_SUCCESS) {
   pr_debug("OPAL async call returned failed [rc=%d]\n",
    rc);
   break;
  }
  break;
 case OPAL_SUCCESS:
  break;
 default:
  pr_debug("OPAL write op-panel call failed [rc=%d]\n", rc);
 }

 opal_async_release_token(token);
 return rc;
}

static ssize_t oppanel_write(struct file *filp, const char __user *userbuf,
        size_t len, loff_t *f_pos)
{
 loff_t f_pos_prev = *f_pos;
 ssize_t ret;
 int rc;

 if (!*f_pos)
  memset(oppanel_data, ' ', oppanel_size);
 else if (*f_pos >= oppanel_size)
  return -EFBIG;

 ret = simple_write_to_buffer(oppanel_data, oppanel_size, f_pos, userbuf,
   len);
 if (ret > 0) {
  rc = __op_panel_update_display();
  if (rc != OPAL_SUCCESS) {
   pr_err_ratelimited("OPAL call failed to write to op panel display [rc=%d]\n",
    rc);
   *f_pos = f_pos_prev;
   return -EIO;
  }
 }
 return ret;
}

static int oppanel_open(struct inode *inode, struct file *filp)
{
 if (!mutex_trylock(&oppanel_mutex)) {
  pr_debug("Device Busy\n");
  return -EBUSY;
 }
 return 0;
}

static int oppanel_release(struct inode *inode, struct file *filp)
{
 mutex_unlock(&oppanel_mutex);
 return 0;
}

static const struct file_operations oppanel_fops = {
 .owner  = THIS_MODULE,
 .llseek  = oppanel_llseek,
 .read  = oppanel_read,
 .write  = oppanel_write,
 .open  = oppanel_open,
 .release = oppanel_release
};

static struct miscdevice oppanel_dev = {
 .minor  = MISC_DYNAMIC_MINOR,
 .name  = "op_panel",
 .fops  = &oppanel_fops
};

static int oppanel_probe(struct platform_device *pdev)
{
 struct device_node *np = pdev->dev.of_node;
 u32 line_len;
 int rc, i;

 rc = of_property_read_u32(np, "#length", &line_len);
 if (rc) {
  pr_err_ratelimited("Operator panel length property not found\n");
  return rc;
 }
 rc = of_property_read_u32(np, "#lines", &num_lines);
 if (rc) {
  pr_err_ratelimited("Operator panel lines property not found\n");
  return rc;
 }
 oppanel_size = line_len * num_lines;

 pr_devel("Operator panel of size %u found with %u lines of length %u\n",
   oppanel_size, num_lines, line_len);

 oppanel_data = kcalloc(oppanel_size, sizeof(*oppanel_data), GFP_KERNEL);
 if (!oppanel_data)
  return -ENOMEM;

 oppanel_lines = kcalloc(num_lines, sizeof(oppanel_line_t), GFP_KERNEL);
 if (!oppanel_lines) {
  rc = -ENOMEM;
  goto free_oppanel_data;
 }

 memset(oppanel_data, ' ', oppanel_size);
 for (i = 0; i < num_lines; i++) {
  oppanel_lines[i].line_len = cpu_to_be64(line_len);
  oppanel_lines[i].line = cpu_to_be64(__pa(&oppanel_data[i *
      line_len]));
 }

 rc = misc_register(&oppanel_dev);
 if (rc) {
  pr_err_ratelimited("Failed to register as misc device\n");
  goto free_oppanel;
 }

 return 0;

free_oppanel:
 kfree(oppanel_lines);
free_oppanel_data:
 kfree(oppanel_data);
 return rc;
}

static void oppanel_remove(struct platform_device *pdev)
{
 misc_deregister(&oppanel_dev);
 kfree(oppanel_lines);
 kfree(oppanel_data);
}

static const struct of_device_id oppanel_match[] = {
 { .compatible = "ibm,opal-oppanel" },
 { },
};

static struct platform_driver oppanel_driver = {
 .driver = {
  .name  = "powernv-op-panel",
  .of_match_table = oppanel_match,
 },
 .probe = oppanel_probe,
 .remove = oppanel_remove,
};

module_platform_driver(oppanel_driver);

MODULE_DEVICE_TABLE(of, oppanel_match);
MODULE_LICENSE("GPL v2");
MODULE_DESCRIPTION("PowerNV Operator Panel LCD Display Driver");
MODULE_AUTHOR("Suraj Jitindar Singh ");

Messung V0.5
C=93 H=95 G=93

¤ Dauer der Verarbeitung: 0.3 Sekunden  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.