/* SPDX-License-Identifier: GPL-2.0-only */ /* * Copyright 2023 Red Hat
*/
#ifndef VDO_CONSTANTS_H #define VDO_CONSTANTS_H
#include <linux/blkdev.h>
#include"types.h"
enum { /* * The maximum number of contiguous PBNs which will go to a single bio submission queue, * assuming there is more than one queue.
*/
VDO_BIO_ROTATION_INTERVAL_LIMIT = 1024,
/* The number of entries on a block map page */
VDO_BLOCK_MAP_ENTRIES_PER_PAGE = 812,
/* The origin of the flat portion of the block map */
VDO_BLOCK_MAP_FLAT_PAGE_ORIGIN = 1,
/* * The height of a block map tree. Assuming a root count of 60 and 812 entries per page, * this is big enough to represent almost 95 PB of logical space.
*/
VDO_BLOCK_MAP_TREE_HEIGHT = 5,
/* The default number of bio submission queues. */
DEFAULT_VDO_BIO_SUBMIT_QUEUE_COUNT = 4,
/* The number of contiguous PBNs to be submitted to a single bio queue. */
DEFAULT_VDO_BIO_SUBMIT_QUEUE_ROTATE_INTERVAL = 64,
/* The number of trees in the arboreal block map */
DEFAULT_VDO_BLOCK_MAP_TREE_ROOT_COUNT = 60,
/* The default size of the recovery journal, in blocks */
DEFAULT_VDO_RECOVERY_JOURNAL_SIZE = 32 * 1024,
/* The default size of each slab journal, in blocks */
DEFAULT_VDO_SLAB_JOURNAL_SIZE = 224,
/* * The initial size of lbn_operations and pbn_operations, which is based upon the expected * maximum number of outstanding VIOs. This value was chosen to make it highly unlikely * that the maps would need to be resized.
*/
VDO_LOCK_MAP_CAPACITY = 10000,
/* The maximum number of logical zones */
MAX_VDO_LOGICAL_ZONES = 60,
/* The maximum number of physical zones */
MAX_VDO_PHYSICAL_ZONES = 16,
/* The base-2 logarithm of the maximum blocks in one slab */
MAX_VDO_SLAB_BITS = 23,
/* The maximum number of slabs the slab depot supports */
MAX_VDO_SLABS = 8192,
/* * The maximum number of block map pages to load simultaneously during recovery or rebuild.
*/
MAXIMUM_SIMULTANEOUS_VDO_BLOCK_MAP_RESTORATION_READS = 1024,
/* The maximum number of entries in the slab summary */
MAXIMUM_VDO_SLAB_SUMMARY_ENTRIES = MAX_VDO_SLABS * MAX_VDO_PHYSICAL_ZONES,
/* The maximum number of total threads in a VDO thread configuration. */
MAXIMUM_VDO_THREADS = 100,
/* The maximum number of VIOs in the system at once */
MAXIMUM_VDO_USER_VIOS = 2048,
/* The only physical block size supported by VDO */
VDO_BLOCK_SIZE = 4096,
/* The number of sectors per block */
VDO_SECTORS_PER_BLOCK = (VDO_BLOCK_SIZE >> SECTOR_SHIFT),
/* The size of a sector that will not be torn */
VDO_SECTOR_SIZE = 512,
/* The physical block number reserved for storing the zero block */
VDO_ZERO_BLOCK = 0,
};
#endif/* VDO_CONSTANTS_H */
Messung V0.5
¤ Dauer der Verarbeitung: 0.12 Sekunden
(vorverarbeitet)
¤
Die Informationen auf dieser Webseite wurden
nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit,
noch Qualität der bereit gestellten Informationen zugesichert.
Bemerkung:
Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.