*************************************************************** * * COMMENT SECTION * * DATE 1989/01/16 EMBEDDED COBOL LANGUAGE * NIST SQL VALIDATION TEST SUITE V6.0 * DISCLAIMER: * This program was written by employees of NIST to test SQL * implementations for conformance to the SQL standards. * NIST assumes no responsibility for any party's use of * this program. * * COB008.PCO * WRITTEN BY: S Hurwitz * * THIS ROUTINE TESTS COBOL DATA TYPES IN SQL LANGUAGE. * * REFERENCES * AMERICAN NATIONAL STANDARD database language - SQL * X3.135-1989 * * SECTION 5.5 <data type> * ANNEX C. <embedded SQL COBOL program> * * ***************************************************************
MOVE"HU"TO uid CALL"AUTHID"USING uid MOVE"not logged in, not"TO uidx EXECSQLSELECT
USER INTO :uidx FROM HU.ECCO END-EXEC if (uid NOT = uidx) then DISPLAY"ERROR: User " uid " expected." DISPLAY"User " uidx " connected." DISPLAY" " STOPRUN END-IF
MOVE 0 TO errcnt DISPLAY "SQL Test Suite, V6.0, Embedded COBOL, cob008.pco" DISPLAY" " DISPLAY "59-byte ID" DISPLAY"TEd Version #" DISPLAY" " * date_time print * ACCEPT TO-DAY FROMDATE ACCEPT THE-TIME FROMTIME DISPLAY"Date run YYMMDD: " TO-DAY " at hhmmssff: " THE-TIME
******************** BEGIN TEST0235 *******************
MOVE SQLCODE TO SQL-COD DISPLAY"After INSERT SQLCODE = ", SQL-COD
DISPLAY" " MOVE 0 TO var1 EXECSQLSELECT * INTO :var1 FROM SV END-EXEC MOVE SQLCODE TO SQL-COD DISPLAY"After SELECT into var1 the SQLCODE = ", SQL-COD DISPLAY"*** to check exact numeric type S9(5)V99 ***" DISPLAY "*** var1 answer should be either 12345.67 or 12345.68 ***" MOVE var1 TO ed-var1 DISPLAY" var1 = ", ed-var1 if (var1 = 12345.67 or var1 = 12345.68) ADD 1 TO cnt END-IF
DISPLAY" " MOVE 0 TO var3 EXECSQLSELECT * INTO :var3 FROM SV END-EXEC MOVE SQLCODE TO SQL-COD DISPLAY"After SELECT into var3 the SQLCODE = ", SQL-COD DISPLAY"*** to check exact numeric type S99999V ***" DISPLAY "*** var3 answer should be either 12345 or 12346 ***" MOVE var3 TO ed-var3 DISPLAY" var3 = ", ed-var3 if ((var3 = 12345) or (var3 = 12346)) ADD 1 TO cnt END-IF
DISPLAY" " MOVE 0 TO var4 EXECSQLSELECT * INTO :var4 FROM SV END-EXEC MOVE SQLCODE TO SQL-COD DISPLAY"After SELECT into var4 the SQLCODE = ", SQL-COD DISPLAY"*** to check exact numeric type S9(6)V9(3) ***" DISPLAY"*** var4 answer should be 12345.678 ***" MOVE var4 TO ed-var4 DISPLAY" var4 = ", ed-var4 if (var4 = 12345.678) ADD 1 TO cnt END-IF
DISPLAY" " MOVE 0 TO var5 EXECSQLSELECT * INTO :var5 FROM SV END-EXEC MOVE SQLCODE TO SQL-COD DISPLAY"After SELECT into var5 the SQLCODE = ", SQL-COD DISPLAY"*** to check exact numeric type S9(5)V9(3) ***" DISPLAY"*** var5 answer should be 12345.678 ***" MOVE var5 TO ed-var5 DISPLAY" var5 = ", ed-var5 if (var5 = 12345.678) ADD 1 TO cnt END-IF
MOVE SQLCODE TO SQL-COD DISPLAY"After INSERT SQLCODE = ", SQL-COD
DISPLAY" " MOVE 0 TO var2 EXECSQLSELECT * INTO :var2 FROM SV END-EXEC MOVE SQLCODE TO SQL-COD DISPLAY"After SELECT into var2, the SQLCODE = ", SQL-COD DISPLAY "*** checks SELECT into exact numeric type S99V ***" DISPLAY "*** from type S9(5)V9(3) ***" DISPLAY "The answer should be a NEGATIVE SQLCODE- - -EXCEPTION!! " MOVE var2 TO ed-var2 DISPLAY" var2 = ", ed-var2 if (SQLCODE < 0 ) ADD 1 TO cnt END-IF
DISPLAY" " MOVE 0 TO var6 EXECSQLSELECT * INTO :var6 FROM SV END-EXEC MOVE SQLCODE TO SQL-COD DISPLAY"After SELECT into var6, the SQLCODE = ", SQL-COD DISPLAY "*** checks SELECT into exact numeric type SV99 ***" DISPLAY "*** from type S9(5)V9(3) ***" DISPLAY "The answer should be a NEGATIVE SQLCODE- - -EXCEPTION!! " MOVE var6 TO ed-var6 DISPLAY" var6 = ", ed-var6 if (SQLCODE < 0 ) ADD 1 TO cnt END-IF
******************** END TEST0236 *******************
**** TESTER MAY CHOOSE TO INSERT CODE FOR errcnt > 0 STOPRUN.
¤ Die Informationen auf dieser Webseite wurden
nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit,
noch Qualität der bereit gestellten Informationen zugesichert.0.15Bemerkung:
(vorverarbeitet)
¤
Die Informationen auf dieser Webseite wurden
nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit,
noch Qualität der bereit gestellten Informationen zugesichert.
Bemerkung:
Die farbliche Syntaxdarstellung ist noch experimentell.