Quellcodebibliothek Statistik Leitseite products/sources/formale Sprachen/C/Linux/drivers/iio/potentiometer/   (Open Source Betriebssystem Version 6.17.9©)  Datei vom 24.10.2025 mit Größe 3 kB image not shown  

Quelle  max5432.c   Sprache: C

 
// SPDX-License-Identifier: GPL-2.0-or-later
/*
 * Maxim Integrated MAX5432-MAX5435 digital potentiometer driver
 * Copyright (C) 2019 Martin Kaiser <martin@kaiser.cx>
 *
 * Datasheet:
 * https://datasheets.maximintegrated.com/en/ds/MAX5432-MAX5435.pdf
 */


#include <linux/i2c.h>
#include <linux/iio/iio.h>
#include <linux/limits.h>
#include <linux/module.h>
#include <linux/mod_devicetable.h>
#include <linux/property.h>

/* All chip variants have 32 wiper positions. */
#define MAX5432_MAX_POS 31

#define MAX5432_OHM_50K   (50  * 1000)
#define MAX5432_OHM_100K  (100 * 1000)

/* Update the volatile (currently active) setting. */
#define MAX5432_CMD_VREG  0x11

struct max5432_data {
 struct i2c_client *client;
 unsigned long ohm;
};

static const struct iio_chan_spec max5432_channels[] = {
 {
  .type = IIO_RESISTANCE,
  .indexed = 1,
  .output = 1,
  .channel = 0,
  .address = MAX5432_CMD_VREG,
  .info_mask_separate = BIT(IIO_CHAN_INFO_RAW),
  .info_mask_shared_by_type = BIT(IIO_CHAN_INFO_SCALE),
 }
};

static int max5432_read_raw(struct iio_dev *indio_dev,
   struct iio_chan_spec const *chan,
   int *val, int *val2, long mask)
{
 struct max5432_data *data = iio_priv(indio_dev);

 if (mask != IIO_CHAN_INFO_SCALE)
  return -EINVAL;

 if (unlikely(data->ohm > INT_MAX))
  return -ERANGE;

 *val = data->ohm;
 *val2 = MAX5432_MAX_POS;

 return IIO_VAL_FRACTIONAL;
}

static int max5432_write_raw(struct iio_dev *indio_dev,
   struct iio_chan_spec const *chan,
   int val, int val2, long mask)
{
 struct max5432_data *data = iio_priv(indio_dev);
 u8 data_byte;

 if (mask != IIO_CHAN_INFO_RAW)
  return -EINVAL;

 if (val < 0 || val > MAX5432_MAX_POS)
  return -EINVAL;

 if (val2 != 0)
  return -EINVAL;

 /* Wiper position is in bits D7-D3. (D2-D0 are don't care bits.) */
 data_byte = val << 3;
 return i2c_smbus_write_byte_data(data->client, chan->address,
   data_byte);
}

static const struct iio_info max5432_info = {
 .read_raw = max5432_read_raw,
 .write_raw = max5432_write_raw,
};

static int max5432_probe(struct i2c_client *client)
{
 struct device *dev = &client->dev;
 struct iio_dev *indio_dev;
 struct max5432_data *data;

 indio_dev = devm_iio_device_alloc(dev, sizeof(struct max5432_data));
 if (!indio_dev)
  return -ENOMEM;

 i2c_set_clientdata(client, indio_dev);

 data = iio_priv(indio_dev);
 data->client = client;
 data->ohm = (unsigned long)device_get_match_data(dev);

 indio_dev->info = &max5432_info;
 indio_dev->channels = max5432_channels;
 indio_dev->num_channels = ARRAY_SIZE(max5432_channels);
 indio_dev->name = client->name;

 return devm_iio_device_register(dev, indio_dev);
}

static const struct of_device_id max5432_dt_ids[] = {
 { .compatible = "maxim,max5432", .data = (void *)MAX5432_OHM_50K  },
 { .compatible = "maxim,max5433", .data = (void *)MAX5432_OHM_100K },
 { .compatible = "maxim,max5434", .data = (void *)MAX5432_OHM_50K  },
 { .compatible = "maxim,max5435", .data = (void *)MAX5432_OHM_100K },
 { }
};
MODULE_DEVICE_TABLE(of, max5432_dt_ids);

static struct i2c_driver max5432_driver = {
 .driver = {
  .name = "max5432",
  .of_match_table = max5432_dt_ids,
 },
 .probe = max5432_probe,
};

module_i2c_driver(max5432_driver);

MODULE_AUTHOR("Martin Kaiser ");
MODULE_DESCRIPTION("max5432-max5435 digital potentiometers");
MODULE_LICENSE("GPL v2");

Messung V0.5
C=97 H=99 G=97

¤ Dauer der Verarbeitung: 0.14 Sekunden  (vorverarbeitet)  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.