Quelle: BV_20_C.py Sprache: Python
# Copyright 2024 Google LLC
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# https://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
import hci_packets as hci
import link_layer_packets as ll
import math
import random
from dataclasses import dataclass
from hci_packets import ErrorCode
from py.bluetooth import Address
from py.controller import ControllerTest
from typing import Optional
ADV_IND = 0x13
ADV_DIRECT_IND = 0x15
ADV_SCAN_IND = 0x12
ADV_EXT_IND = 0x02
@dataclass
class TestRound:
advertising_event_properties: int
target_address: Optional[Address]
scan_data_length: int
class Test(ControllerTest):
# LL/DDI/SCN/BV-20-C [Extended Scanning, Active – LE 1M PHY, Core 5.0]
#
# Verify that a scanner IUT detects and requests additional information from
# advertisements received and reports the results from the Controller. The
# Lower Tester advertises using scannable extended advertising events on one
# channel at a time and expects the IUT to report the advertising to the
# Upper Tester. Both directed and undirected advertising events are tested.
async def test(self):
# Test rounds.
# Note: some tests are skipped as no distinction is made between
# ADV_EXT_IND, AUX_ADV_IND, AUX_CHAIN_IND.
controller = self.controller
invalid_address = Address( "11:22:33:44:55:66")
test_rounds = [
TestRound(ADV_IND, None, 0),
TestRound(ADV_IND, None, 31),
TestRound(ADV_SCAN_IND, None, 0),
TestRound(ADV_SCAN_IND, None, 31),
TestRound(ADV_EXT_IND, None, 1),
TestRound(ADV_EXT_IND, controller.address, 1),
TestRound(ADV_EXT_IND, invalid_address, 1),
TestRound(ADV_EXT_IND, None, 191),
TestRound(ADV_EXT_IND, None, 382),
TestRound(ADV_EXT_IND, None, 1647),
]
# 1. For each round as specified in Table 4.2-35 based on Table 4.2-36, if ScanData Length is less
# than or equal to the “Scan Max Data” then perform steps 2–8 and otherwise omit this round.
for test_round in test_rounds:
await self.steps_2_8(**vars(test_round))
async def steps_2_8(self, advertising_event_properties: int, target_address: Optional[ Address],
scan_data_length: int):
controller = self.controller
lower_tester_address = Address("ca:fe:ca:fe:00:01")
# 2. The Upper Tester sends an HCI_LE_Set_Extended_Scan_Parameters command to the IUT. The
# Scanning_PHYs parameter is set as specified in Table 4.2-35, Scan_Type[0] set to 0x01 (Active
# Scanning), Scan_Interval[0] set to 0x0010, and Scan_Window[0] set to 0x0010.
# Own_Address_Type is set to 0x00 (Public Device Address), and Scanning_Filter_Policy is set to
# 0x00 (Accept All) and receives a successful HCI_Command_Complete.
controller.send_cmd(
hci.LeSetExtendedScanParameters(
own_address_type=hci.OwnAddressType.PUBLIC_DEVICE_ADDRESS,
scanning_filter_policy=hci.LeScanningFilterPolicy.ACCEPT_ALL,
scanning_phys=0x1,
scanning_phy_parameters=[
hci.ScanningPhyParameters(le_scan_type=hci.LeScanType.ACTIVE,
le_scan_interval=0x0010,
le_scan_window=0x0010)
]))
await self.expect_evt(
hci.LeSetExtendedScanParametersComplete(status=ErrorCode.SUCCESS,
num_hci_command_packets=1))
# 3. The Upper Tester sends an HCI_LE_Set_Extended_Scan_Enable command to the IUT to enable
# scanning. Filter_Duplicates, Duration, and Period are all set to zero and receive a successful
# HCI_Command_Complete.
controller.send_cmd(
hci.LeSetExtendedScanEnable(enable=hci.Enable.ENABLED,
filter_duplicates=hci.Enable.DISABLED,
duration=0,
period=0))
await self.expect_evt(
hci.LeSetExtendedScanEnableComplete(status=ErrorCode.SUCCESS,
num_hci_command_packets=1))
# 4. The Lower Tester begins advertising on the channel as specified in Table 4.2-35 using the PDU
# Type specified in Table 4.2-36 for this round. If AUX_ADV_IND is included in the round, the
# ADV_EXT_IND includes an AuxPtr that refers to the AUX_ADV_IND on the PHY as specified in
# Table 4.2-35, and all fields specified should be included with the AUX_ADV_IND only. If AdvA is
# specified, the appropriate PDU includes the field, where “LT” equals the Lower Tester address. If
# TargetA is specified, the appropriate PDU includes the field, where “IUT” equals the IUT address
# and “Not IUT” equals a random address other than the IUT address. Repeat for at least 20
# advertising intervals or until step 5 occurs.
connectable = (advertising_event_properties & 0x1) != 0
scannable = (advertising_event_properties & 0x2) != 0
directed = (advertising_event_properties & 0x4) != 0
high_duty_cycle = (advertising_event_properties & 0x8) != 0
legacy = (advertising_event_properties & 0x10) != 0
if legacy:
if advertising_event_properties == ADV_IND:
advertising_type = ll.LegacyAdvertisingType.ADV_IND
elif advertising_event_properties == ADV_DIRECT_IND:
advertising_type = ll.LegacyAdvertisingType.ADV_DIRECT_IND
elif advertising_event_properties == ADV_SCAN_IND:
advertising_type = ll.LegacyAdvertisingType.ADV_SCAN_IND
elif advertising_event_properties == ADV_NONCONN_IND:
advertising_type = ll.LegacyAdvertisingType.ADV_NONCONN_IND
pdu = ll.LeLegacyAdvertisingPdu(source_address=lower_tester_address,
destination_address=target_address or Address(),
advertising_address_type=ll.AddressType.PUBLIC,
target_address_type=ll.AddressType.PUBLIC,
advertising_type=advertising_type,
advertising_data=[])
else:
pdu = ll.LeExtendedAdvertisingPdu(source_address=lower_tester_address,
destination_address=target_address or Address(),
advertising_address_type=ll.AddressType.PUBLIC,
target_address_type=ll.AddressType.PUBLIC,
connectable=connectable,
scannable=scannable,
directed=not target_address is None,
sid=0,
tx_power=0x7f,
primary_phy=ll.PhyType.LE_1M,
secondary_phy=ll.PhyType.NO_PACKETS,
advertising_data=[])
# 5. For undirected advertisements or advertisements directed at the IUT, the Lower Tester receives
# either a SCAN_REQ (if advertising with legacy PDUs) or an AUX_SCAN_REQ (if advertising with
# extended PDUs) on the appropriate advertising channel. The ScanA field is set to the IUT’s
# address, and the AdvA address is set to the Lower Tester’s address. The Upper Tester receives
# an HCI_LE_Extended_Advertising_Report event from the IUT with an Event_Type where bit 3
# (Scan response) is not set, the Data Status in the Event_Type field is set to Complete (0b00),
# Periodic_Advertising_Interval is set to 0, and no advertising data. If the advertisements were
# directed but TargetA is not the IUT, skip to step 8.
for n in range(3):
if not legacy:
sid = random.randint(0, 15)
pdu.sid = sid
else:
sid = 0xff
controller.send_ll(pdu, rssi=0)
if target_address and target_address != controller.address:
# If the controller still emits an event, the error
# will appear in the subsequent rounds.
continue
await self.expect_evt(
hci.LeExtendedAdvertisingReport(responses=[
hci.LeExtendedAdvertisingResponse(
connectable=connectable,
scannable=scannable,
directed=not target_address is None,
scan_response=False,
legacy=legacy,
data_status=hci.DataStatus.COMPLETE,
address_type=hci.AddressType.PUBLIC_DEVICE_ADDRESS,
address=lower_tester_address,
primary_phy=hci.PrimaryPhyType.LE_1M,
secondary_phy=hci.SecondaryPhyType.NO_PACKETS,
advertising_sid=sid,
tx_power=0x7f,
rssi=0,
periodic_advertising_interval=0,
direct_address_type=hci.DirectAdvertisingAddressType.
NO_ADDRESS_PROVIDED if not target_address else hci.
DirectAdvertisingAddressType.PUBLIC_DEVICE_ADDRESS,
direct_address=target_address or Address(),
advertising_data=[])
]))
await self.expect_ll(
ll.LeScan(source_address=controller.address,
destination_address=lower_tester_address,
scanning_address_type=ll.AddressType.PUBLIC,
advertising_address_type=ll.AddressType.PUBLIC))
advertising_data = [random.randint(1, 254) for n in range(scan_data_length)]
# 6. Perform step 6A or 6B depending on the PDU sent by the IUT in step 5.
# Alternative 6A (The IUT sent a SCAN_REQ in step 5):
# 6A.1 The Lower Tester responds with a SCAN_RSP packet to the IUT T_IFS after the end
# of the SCAN_REQ PDU. If ScanData is specified, the SCAN_RSP PDU includes the
# field populated with random octets from 1 to 254 of the specified count.
# Alternative 6B (The IUT sent an AUX_SCAN_REQ in step 5):
# 6B.1 The Lower Tester responds with an AUX_SCAN_RSP packet to the IUT T_IFS after
# the end of the AUX_SCAN_REQ PDU with an AdvMode of 0b00. If ScanData is
# specified, the AUX_SCAN_RSP PDU includes the AdvData field populated with
# random octets from 1 to 254 of the specified count. If the ScanData is greater in
# length than will fit in one PDU, the Lower Tester includes an AuxPtr field and sends
# one or more AUX_CHAIN_IND PDUs containing the remaining data. Each PDU
# except the last contains as much AdvData as can fit.
controller.send_ll(ll.LeScanResponse(source_address=lower_tester_address,
destination_address=controller.address,
advertising_address_type=ll.AddressType.PUBLIC,
scan_response_data=advertising_data),
rssi=0)
# 7. If the Lower Tester sent a scan response in step 6, the Upper Tester receives one or more
# HCI_LE_Extended_Advertising_Report events from the IUT with an Event_Type where bit 3
# (Scan response) is set, and Periodic_Advertising_Interval is set to 0. If ScanData was included in
# the response, the Upper Tester receives the data included in one of the advertising packets. If
# ScanData is sent to the Upper Tester in multiple reports, the Data Status in the Event_Type field
# for each report except the last is set to “Incomplete, more data to come”, 0b01. The Event_Type
# field for the last report sent with advertisement data is set to “Complete”, 0b00.
offset = 0
max_fragment_length = 229
num_fragments = math.ceil(scan_data_length / max_fragment_length) or 1
for n in range(num_fragments):
remaining_length = scan_data_length - offset
fragment_length = min(max_fragment_length, remaining_length)
data_status = hci.DataStatus.CONTINUING if remaining_length > max_fragment_length else hci.DataStatus.COMPLETE
await self.expect_evt(
hci.LeExtendedAdvertisingReport(responses=[
hci.LeExtendedAdvertisingResponse(
connectable=connectable,
scannable=scannable,
directed=False,
scan_response=True,
legacy=legacy,
data_status=data_status,
address_type=hci.AddressType.PUBLIC_DEVICE_ADDRESS,
address=lower_tester_address,
primary_phy=hci.PrimaryPhyType.LE_1M,
secondary_phy=hci.SecondaryPhyType.NO_PACKETS,
# TODO SID should be set in scan response PDU
advertising_sid=0xff,
tx_power=0x7f,
rssi=0,
periodic_advertising_interval=0,
direct_address_type=hci.DirectAdvertisingAddressType.
NO_ADDRESS_PROVIDED,
direct_address=Address(),
advertising_data=advertising_data[offset:offset + fragment_length])
]))
offset += fragment_length
# 8. The Upper Tester sends an HCI_LE_Set_Scan_Enable to the IUT to disable scanning and
# receives an HCI_Command_Complete event in response.
controller.send_cmd(hci.LeSetExtendedScanEnable(enable=hci.Enable.DISABLED))
await self.expect_evt(
hci.LeSetExtendedScanEnableComplete(status=ErrorCode.SUCCESS,
num_hci_command_packets=1))