Quellcodebibliothek Statistik Leitseite products/Sources/formale Sprachen/C/Firefox/intl/icu/source/allinone/   (Browser von der Mozilla Stiftung Version 136.0.1©)  Datei vom 10.2.2025 mit Größe 3 kB image not shown  

Quelle  icucheck.bat   Sprache: BAT

 
@echo off
REM Copyright (C) 2016 and later: Unicode, Inc. and others.
REM License & terms of use: http://www.unicode.org/copyright.html
REM  ********************************************************************
REM  * COPYRIGHT:
REM  * Copyright (c) 2010-2014, International Business Machines Corporation
REM  * and others. All Rights Reserved.
REM  ********************************************************************

set ICU_ARCH=%1
set ICU_DBRL=%2

if "%1" == "" (
echo Usage: %0 "x86 or x64 or ARM or ARM64"  "Debug or Release"
exit /b 1
)

if "%2" == "" (
echo Usage: %0 %1 "Debug or Release"
exit /b 1
)

set ICU_OPATH=%PATH%

set ICU_ICUDIR="%~dp0"\..\..

if "%ICU_ARCH%" == "x64" (
    set ICU_BINDIR=%~dp0\..\..\bin64
) else if "%ICU_ARCH%" == "ARM64" (
    set ICU_BINDIR=%~dp0\..\..\binARM64
) else if "%ICU_ARCH%" == "ARM" (
    set ICU_BINDIR=%~dp0\..\..\binARM
) else (
    set ICU_BINDIR=%~dp0\..\..\bin
)

set PATH=%ICU_BINDIR%;%PATH%

echo testing ICU in %ICU_ICUDIR%  arch=%ICU_ARCH% type=%ICU_DBRL%
pushd %ICU_ICUDIR%

@rem factor these out
set ICUINFO_CMD=%ICU_ICUDIR%\source\tools\icuinfo\%ICU_ARCH%\%ICU_DBRL%\icuinfo.exe
set INTLTEST_CMD=%ICU_ICUDIR%\source\test\intltest\%ICU_ARCH%\%ICU_DBRL%\intltest.exe
set IOTEST_CMD=%ICU_ICUDIR%\source\test\iotest\%ICU_ARCH%\%ICU_DBRL%\iotest.exe
set CINTLTST_CMD=%ICU_ICUDIR%\source\test\cintltst\%ICU_ARCH%\%ICU_DBRL%\cintltst.exe
set LETEST_CMD=%ICU_ICUDIR%\source\test\letest\%ICU_ARCH%\%ICU_DBRL%\letest.exe

set ICUFAILED=
set ICURUN=
set ICUFAILCNT=0

@echo on

@set THT=icuinfo
@echo ==== %THT% =========================================================================
%ICUINFO_CMD% %ICUINFO_OPTS%

@IF %ERRORLEVEL% EQU 0 GOTO OK_%THT%
@set ICUFAILED=%ICUFAILED% %THT%
@set ICUFAILCNT=1
:OK_icuinfo
@set ICURUN=%ICURUN% %THT%

@set THT=intltest
@echo ==== %THT% =========================================================================
@cd %ICU_ICUDIR%\source\test\intltest
%INTLTEST_CMD% %INTLTEST_OPTS%

@IF %ERRORLEVEL% EQU 0 GOTO OK_%THT%
@set ICUFAILED=%ICUFAILED% %THT%
@set ICUFAILCNT=1
:OK_intltest
@set ICURUN=%ICURUN% %THT%

@set THT=iotest
@echo ==== %THT% =========================================================================
@cd %ICU_ICUDIR%\source\test\iotest
%IOTEST_CMD% %IOTEST_OPTS%

@IF %ERRORLEVEL% EQU 0 GOTO OK_%THT%
@set ICUFAILED=%ICUFAILED% %THT%
@set ICUFAILCNT=1
:OK_IOTEST
@set ICURUN=%ICURUN% %THT%

@set THT=cintltst
@echo ==== %THT% =========================================================================
@cd %ICU_ICUDIR%\source\test\cintltst
%CINTLTST_CMD% %CINTLTST_OPTS%

@IF %ERRORLEVEL% EQU 0 GOTO OK_%THT%
@set ICUFAILED=%ICUFAILED% %THT%
@set ICUFAILCNT=1
:OK_cintltst
@set ICURUN=%ICURUN% %THT%

@REM  (Layout is deprecated - this would require HarfBuzz)
@REM  @set THT=letest
@REM  @echo ==== %THT% =========================================================================
@REM  @cd %ICU_ICUDIR%\source\test\letest
@REM  %LETST_CMD% %LETEST_OPTS%

@REM  @IF %ERRORLEVEL% EQU 0 GOTO OK_%THT%
@REM  @set ICUFAILED=%ICUFAILED% %THT%
@REM  @set ICUFAILCNT=1
@REM  :OK_letest
@REM  @set ICURUN=%ICURUN% %THT%

@echo off

REM clean up
set PATH=%ICU_OPATH%
REM unset ICU_OPATH
popd

@REM done

echo -
echo -
echo -
echo ============================================================
echo Summary: ICU in %ICU_ICUDIR%  arch=%ICU_ARCH% type=%ICU_DBRL%
echo -
echo Tests Run    : %ICURUN%

if %ICUFAILCNT% == 0 (
 echo " - All Passed!"
 exit /b 0
)
echo Failing Tests: %ICUFAILED%
echo -
echo FAILED!

exit /b 1

Messung V0.5
C=85 H=91 G=87

¤ Dauer der Verarbeitung: 0.13 Sekunden  (vorverarbeitet)  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.