IDENTIFICATION DIVISION.
PROGRAM-ID. DML036.
ENVIRONMENT DIVISION.
CONFIGURATION SECTION.
SOURCE-COMPUTER. xyz.
OBJECT-COMPUTER. xyz.
DATA DIVISION.
WORKING-STORAGE SECTION.
* EMBEDDED COBOL (file "DML036.PCO")
****************************************************************
*
* COMMENT SECTION
*
* DATE 1987/08/21 EMBEDDED COBOL LANGUAGE
* NIST SQL VALIDATION TEST SUITE V6.0
* DISCLAIMER:
* This program was written by employees of NIST to test SQL
* implementations for conformance to the SQL standards.
* NIST assumes no responsibility for any party's use of
* this program.
*
* DML036.PCO
* WRITTEN BY: HU YANPING
* TRANSLATED AUTOMATICALLY FROM EMBEDDED C BY CHRIS SCHANZLE
*
* THIS PROGRAM TESTS THE HANDLING OF CHARACTER STRING (SPACE
* FILLING, TRUNCATING ETC.) INTO TEST COLUMNS. IT ALSO TESTS
* THE USE OF NUMERIC DATATYPES IN INSERT STATEMENTS.
*
* REFERENCES
* AMERICAN NATIONAL STANDARD database language - SQL
* X3.135-1989
*
* SECTION 8.3 <declare cursor>
* SECTION 8.6 <fetch statement>
* SECTION 8.7 <insert statement>
* SECTION 8.8 <open statement>
*
****************************************************************
EXEC SQL BEGIN DECLARE SECTION END-EXEC
01 indic1 PIC S9(4) DISPLAY SIGN LEADING SEPARATE.
01 indic2 PIC S9(4) DISPLAY SIGN LEADING SEPARATE.
01 t13 PIC X(4).
01 t23 PIC S9(2) DISPLAY SIGN LEADING SEPARATE.
01 t33 PIC X(4).
01 uid PIC X(18).
01 uidx PIC X(18).
EXEC SQL END DECLARE SECTION END-EXEC
01 SQLCODE PIC S9(9) COMP.
01 errcnt PIC S9(4) DISPLAY SIGN LEADING SEPARATE.
01 ii PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 SQL-COD PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 DISP1 PIC S9(4) DISPLAY SIGN LEADING SEPARATE.
01 DISP2 PIC S9(4) DISPLAY SIGN LEADING SEPARATE.
* date_time declaration *
01 TO-DAY PIC 9(6).
01 THE-TIME PIC 9(8).
PROCEDURE DIVISION.
P0.
MOVE "HU" TO uid
CALL "AUTHID" USING uid
MOVE "not logged in, not" TO uidx
EXEC SQL SELECT
USER INTO :uidx FROM HU.ECCO END-EXEC
if (uid NOT = uidx) then
DISPLAY "ERROR: User " uid " expected."
DISPLAY "User " uidx " connected."
DISPLAY " "
STOP RUN
END-IF
MOVE 0 TO errcnt
DISPLAY
"SQL Test Suite, V6.0, Embedded COBOL, dml036.pco"
DISPLAY " "
DISPLAY
"59-byte ID"
DISPLAY "TEd Version #"
DISPLAY " "
* date_time print *
ACCEPT TO-DAY FROM DATE
ACCEPT THE-TIME FROM TIME
DISPLAY "Date run YYMMDD: " TO-DAY " at hhmmssff: " THE-TIME
******************** BEGIN TEST0166 *******************
DISPLAY " TEST0166 "
DISPLAY " Insert with indicators (-1) (5.6 GR1) "
DISPLAY " - - - - - - - - - - - - - - - - - -"
MOVE "zzzz" TO t13
MOVE "zzzz" TO t33
MOVE 23 TO t23
MOVE -1 TO indic2
MOVE -1 TO indic1
EXEC SQL INSERT INTO TMP
VALUES(:t13, :t23 :indic1, :t33 :indic2) END-EXEC
MOVE SQLCODE TO SQL-COD
MOVE 0 TO indic2
MOVE 0 TO indic1
EXEC SQL SELECT *
INTO :t13, :t23 :indic1, :t33 :indic2
FROM TMP
WHERE T1='zzzz' END-EXEC
MOVE SQLCODE TO SQL-COD
MOVE indic1 TO DISP1
MOVE indic2 TO DISP2
DISPLAY " indic1 = ", DISP1 ", indic2 = ", DISP2 " "
EXEC SQL ROLLBACK WORK END-EXEC
MOVE SQLCODE TO SQL-COD
if (indic1 = -1 AND indic2 = -1) then
DISPLAY " *** pass ***"
DISPLAY
"=================================================="
EXEC SQL INSERT INTO TESTREPORT
VALUES('0166','pass','PCO') END-EXEC
MOVE SQLCODE TO SQL-COD
else
DISPLAY " dml036.pco *** fail ***"
DISPLAY
"=================================================="
EXEC SQL INSERT INTO TESTREPORT
VALUES('0166','fail','PCO') END-EXEC
ADD 1 TO errcnt
MOVE SQLCODE TO SQL-COD
END-IF
DISPLAY " "
EXEC SQL COMMIT WORK END-EXEC
MOVE SQLCODE TO SQL-COD
******************** END TEST0166 *******************
**** TESTER MAY CHOOSE TO INSERT CODE FOR errcnt > 0
STOP RUN.
* **** Procedures for PERFORM statements
¤ Dauer der Verarbeitung: 0.1 Sekunden
(vorverarbeitet)
¤
|
Haftungshinweis
Die Informationen auf dieser Webseite wurden
nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit,
noch Qualität der bereit gestellten Informationen zugesichert.
Bemerkung:
Die farbliche Syntaxdarstellung ist noch experimentell.
|