* Standard COBOL (file "SDL033.SCO") calling SQL * procedures in file "SDL033.MCO". * STANDARD COBOL (file "SDL033.SCO")
**************************************************************** * * COMMENT SECTION * * DATE 1992/06/16 STANDARD COBOL LANGUAGE * NIST SQL VALIDATION TEST SUITE V6.0 * DISCLAIMER: * This program was written by employees of NIST to test SQL * implementations for conformance to the SQL standards. * NIST assumes no responsibility for any party's use of * this program. * * SDL033.SCO * WRITTEN BY: DAVID W. FLATER * * THIS ROUTINE TESTS THE SCHEMA DEFINITION LANGUAGE FOR SQL. * * REFERENCES * ANSI SQL-1992 * 11.36 <grant statement> * ****************************************************************
*Part one: make sure we can do everything to the view.
DISPLAY"DELETE FROM FLATER.VS1 WHERE C2 = 1;" DISPLAY"SELECT COUNT(*) FROM FLATER.VS1;" * EXEC SQL DELETE FROM FLATER.VS1 WHERE C2 = 1; CALL"SUB2"USING SQLCODE MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii COMPUTE cc1 = -1 * EXEC SQL SELECT COUNT(*) INTO :cc1 FROM FLATER.VS1; CALL"SUB3"USING SQLCODE cc1 MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO i DISPLAY"SQLCODE should be 0, 0; its value is ", ii ", ", i DISPLAY"COUNT should be 1; its value is ", cc1
if (ii NOT = 0 OR cc1 NOT = 1 OR i NOT = 0) then MOVE 0 TO flag END-IF
DISPLAY"INSERT INTO FLATER.VS1 VALUES (0,7);" * EXEC SQL INSERT INTO FLATER.VS1 VALUES (0,7); CALL"SUB4"USING SQLCODE MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be 0; its value is ", ii
if (ii NOT = 0) then MOVE 0 TO flag END-IF
DISPLAY"UPDATE FLATER.VS1 SET C2 = 8 WHERE C2 = 7;" * EXEC SQL UPDATE FLATER.VS1 * SET C2 = 8 * WHERE C2 = 7; CALL"SUB5"USING SQLCODE MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be 0; its value is ", ii
if (ii NOT = 0) then MOVE 0 TO flag END-IF
DISPLAY"SELECT C1, C2 INTO :cc1, :cc2 FROM FLATER.VS1" DISPLAY" WHERE C2 = 0;" COMPUTE cc1 = -1 COMPUTE cc2 = -1 * EXEC SQL SELECT C1, C2 INTO :cc1, :cc2 * FROM FLATER.VS1 * WHERE C2 = 0; CALL"SUB6"USING SQLCODE cc1 cc2 MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be 0; its value is ", ii DISPLAY"cc1 should be 0; its value is ", cc1 DISPLAY"cc2 should be 0; its value is ", cc2
if (ii NOT = 0 OR cc1 NOT = 0 OR cc2 NOT = 0) then MOVE 0 TO flag END-IF
*Part two: make sure we can't do anything to the table.
DISPLAY"DELETE FROM FLATER.BASE_VS1;" * EXEC SQL DELETE FROM FLATER.BASE_VS1; CALL"SUB8"USING SQLCODE MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be < 0; its value is ", ii
if (ii NOT < 0) then MOVE 0 TO flag END-IF
DISPLAY"SELECT COUNT(*) FROM FLATER.VS1;" COMPUTE tmpcnt = -1 * EXEC SQL SELECT COUNT(*) INTO :tmpcnt * FROM FLATER.VS1; CALL"SUB9"USING SQLCODE tmpcnt MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be 0; its value is ", ii DISPLAY"COUNT should be 2; its value is ", tmpcnt
if (ii NOT = 0 OR tmpcnt NOT = 2) then MOVE 0 TO flag END-IF
DISPLAY"INSERT INTO FLATER.BASE_VS1 VALUES (0,7);" * EXEC SQL INSERT INTO FLATER.BASE_VS1 VALUES (0,7); CALL"SUB10"USING SQLCODE MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be < 0; its value is ", ii
if (ii NOT < 0) then MOVE 0 TO flag END-IF
DISPLAY"SELECT COUNT(*) FROM FLATER.VS1;" COMPUTE tmpcnt = -1 * EXEC SQL SELECT COUNT(*) INTO :tmpcnt * FROM FLATER.VS1; CALL"SUB11"USING SQLCODE tmpcnt MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be 0; its value is ", ii DISPLAY"COUNT should be 2; its value is ", tmpcnt
if (ii NOT = 0 OR tmpcnt NOT = 2) then MOVE 0 TO flag END-IF
DISPLAY"UPDATE FLATER.BASE_VS1 SET C2 = 1;" * EXEC SQL UPDATE FLATER.BASE_VS1 * SET C2 = 1; CALL"SUB12"USING SQLCODE MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be < 0; its value is ", ii
if (ii NOT < 0) then MOVE 0 TO flag END-IF
DISPLAY"SELECT COUNT(*) FROM FLATER.VS1" DISPLAY"WHERE C2 = 1;" COMPUTE tmpcnt = -1 * EXEC SQL SELECT COUNT(*) INTO :tmpcnt * FROM FLATER.VS1 WHERE C2 = 1; CALL"SUB13"USING SQLCODE tmpcnt MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be 0; its value is ", ii DISPLAY"COUNT should be 1; its value is ", tmpcnt
if (ii NOT = 0 OR tmpcnt NOT = 1) then MOVE 0 TO flag END-IF
COMPUTE cc1 = -1 DISPLAY"SELECT COUNT(*) FROM FLATER.BASE_VS1;" * EXEC SQL SELECT COUNT(*) INTO :cc1 FROM FLATER.BASE_VS1 * ; CALL"SUB14"USING SQLCODE cc1 MOVE SQLCODE TO SQL-COD MOVE SQLCODE TO ii DISPLAY"SQLCODE should be < 0; its value is ", ii DISPLAY"COUNT should NOT be 4; its value is ", cc1
if (ii NOT < 0 OR cc1 = 4) then MOVE 0 TO flag END-IF
Die Informationen auf dieser Webseite wurden
nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit,
noch Qualität der bereit gestellten Informationen zugesichert.
Bemerkung:
Die farbliche Syntaxdarstellung ist noch experimentell.