IDENTIFICATION DIVISION.
PROGRAM-ID. MPB008.
ENVIRONMENT DIVISION.
CONFIGURATION SECTION.
SOURCE-COMPUTER. xyz.
OBJECT-COMPUTER. xyz.
DATA DIVISION.
WORKING-STORAGE SECTION.
* Standard COBOL (file "MPB008.SCO") calling SQL
* procedures in file "MPB008.MCO".
* STANDARD COBOL (file "MPB008.SCO")
****************************************************************
*
* COMMENT SECTION
*
* DATE 1992/07/31 STANDARD COBOL LANGUAGE
* NIST SQL VALIDATION TEST SUITE V6.0
* DISCLAIMER:
* This program was written by employees of NIST to test SQL
* implementations for conformance to the SQL standards.
* NIST assumes no responsibility for any party's use of
* this program.
*
* MPB008.SCO
* WRITTEN BY: David W. Flater
*
* THIS PROGRAM IS PART B OF A TWO-PART PROGRAM(A & B) THAT
* TESTS THE CONCURRENCY OF SQL
*
* REFERENCES
* ANSI SQL-1992
* 4.28 SQL-transactions
*
****************************************************************
* EXEC SQL BEGIN DECLARE SECTION END-EXEC
01 uid PIC X(18).
01 knum PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 uidx PIC X(18).
* EXEC SQL END DECLARE SECTION END-EXEC
01 i PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 j PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 SQLCODE PIC S9(9) COMP.
01 errcnt PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
*date_time declaration
01 TO-DAY PIC 9(6).
01 THE-TIME PIC 9(8).
01 code1 PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 pauze PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 pauze2 PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 loops PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 flcnt PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 mxfail PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 SQL-COD PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
PROCEDURE DIVISION.
P0.
MOVE "SULLIVAN1" TO uid
CALL "AUTHID" USING uid
MOVE "not logged in, not" TO uidx
* EXEC SQL SELECT USER INTO :uidx FROM HU.ECCO;
CALL "SUB1" USING SQLCODE uidx
MOVE SQLCODE TO SQL-COD
if (uid NOT = uidx) then
DISPLAY "ERROR: User ", uid " expected. User ", uidx "
- " connected"
STOP RUN
END-IF
MOVE 0 TO errcnt
DISPLAY
"SQL Test Suite, V6.0, Standard COBOL, mpb008.sco"
DISPLAY
"59-byte ID"
DISPLAY "TEd Version #"
*date_time print
ACCEPT TO-DAY FROM DATE
ACCEPT THE-TIME FROM TIME
DISPLAY "Date run YYMMDD: " TO-DAY " at hhmmssff: " THE-TIME
MOVE 1 TO pauze
MOVE 1 TO loops
MOVE 0 TO flcnt
MOVE 50 TO mxfail
******************** BEGIN TEST0517 *******************
DISPLAY " TEST0517 "
DISPLAY " Transactions serializable: Twins Problem"
DISPLAY "Reference ANSI SQL-1992 section 4.28
- " SQL-transactions"
DISPLAY " - - - - - - - - - - - - - - - - - - -"
DISPLAY "*** This program is part B of a two-part"
DISPLAY "*** program (A & B)."
DISPLAY " This is Program B which starts after Program A...
- " "
* -----Synchronization-----
.
P105.
MOVE 0 TO knum
* EXEC SQL SELECT COUNT(*)
* INTO :knum
* FROM MP8_NEXTKEY WHERE AUTHOR = 'A';
CALL "SUB2" USING SQLCODE knum
MOVE SQLCODE TO SQL-COD
* EXEC SQL COMMIT WORK;
CALL "SUB3" USING SQLCODE
MOVE SQLCODE TO SQL-COD
*are we in sync?
if (knum = 0) then
DISPLAY " PLEASE start program MPA008!!! "
GO TO P105
END-IF
.
P106.
MOVE 0 TO code1
* EXEC SQL INSERT INTO MP8_NEXTKEY (KEYNUM,AUTHOR)
* VALUES(2, 'B');
CALL "SUB4" USING SQLCODE
MOVE SQLCODE TO SQL-COD
if (SQLCODE NOT = 0) then
MOVE 1 TO code1
END-IF
* EXEC SQL COMMIT WORK;
CALL "SUB5" USING SQLCODE
MOVE SQLCODE TO SQL-COD
if (SQLCODE NOT = 0) then
MOVE 1 TO code1
END-IF
if (code1 NOT = 0) then
* EXEC SQL ROLLBACK WORK;
CALL "SUB6" USING SQLCODE
MOVE SQLCODE TO SQL-COD
DISPLAY "Retrying synchronization logic."
GO TO P106
END-IF
*YES, we are in sync!
DISPLAY "Transaction B Starts!! "
*date_time print
ACCEPT TO-DAY FROM DATE
ACCEPT THE-TIME FROM TIME
DISPLAY "Date run YYMMDD: " TO-DAY " at hhmmssff: " THE-TIME
DISPLAY " "
DISPLAY "IF this test lasts too long, DEADLOCK"
DISPLAY "has taken place, STOP this test!"
DISPLAY " "
DISPLAY "This part of the test loops continuously trying
- " to"
DISPLAY "insert a duplicate row into MP8_AA. If it
- " succeeds,"
DISPLAY "there has been a serializability or unique
- " constraint"
DISPLAY "failure."
DISPLAY " "
.
P101.
DISPLAY "INSERT INTO MP8_AA VALUES (3,'B');"
* EXEC SQL INSERT INTO MP8_AA VALUES (3,'B');
CALL "SUB7" USING SQLCODE
MOVE SQLCODE TO SQL-COD
if (SQLCODE < 0) then
GO TO P120
END-IF
DISPLAY "COMMIT WORK;"
* EXEC SQL COMMIT WORK;
CALL "SUB8" USING SQLCODE
MOVE SQLCODE TO SQL-COD
if (SQLCODE NOT < 0) then
GO TO P166
END-IF
.
P120.
COMPUTE flcnt = flcnt + 1
if (flcnt > mxfail) then
GO TO P180
END-IF
DISPLAY "*** Negative SQLCODE (Deadlock or UNIQUE
- " violation?) ***"
*date_time print
ACCEPT TO-DAY FROM DATE
ACCEPT THE-TIME FROM TIME
DISPLAY "Date run YYMMDD: " TO-DAY " at hhmmssff: " THE-TIME
DISPLAY "Restarting transaction"
* EXEC SQL ROLLBACK WORK;
CALL "SUB9" USING SQLCODE
MOVE SQLCODE TO SQL-COD
GO TO P101
.
P180.
DISPLAY " "
DISPLAY "Maximum number of negative SQLCODEs exceeded"
*date_time print
ACCEPT TO-DAY FROM DATE
ACCEPT THE-TIME FROM TIME
DISPLAY "Date run YYMMDD: " TO-DAY " at hhmmssff: " THE-TIME
DISPLAY "THIS IS CORRECT BEHAVIOR FOR THIS TEST."
* EXEC SQL ROLLBACK WORK;
CALL "SUB10" USING SQLCODE
MOVE SQLCODE TO SQL-COD
GO TO P198
.
P166.
DISPLAY " "
*date_time print
ACCEPT TO-DAY FROM DATE
ACCEPT THE-TIME FROM TIME
DISPLAY "Date run YYMMDD: " TO-DAY " at hhmmssff: " THE-TIME
DISPLAY "TRANSACTION COMPLETED--THIS SHOULD NOT HAVE
- " HAPPENED!!"
DISPLAY " mpb008.sco *** fail *** "
* EXEC SQL INSERT INTO HU.TESTREPORT
* VALUES('0517','fail','MCO');
CALL "SUB11" USING SQLCODE
MOVE SQLCODE TO SQL-COD
COMPUTE errcnt = errcnt + 1
* EXEC SQL COMMIT WORK;
CALL "SUB12" USING SQLCODE
MOVE SQLCODE TO SQL-COD
.
P198.
DISPLAY " "
DISPLAY
"===================================================="
******************** END TEST0517 *******************
**** TESTER MAY CHOOSE TO INSERT CODE FOR errcnt > 0
STOP RUN.
* **** Procedures for PERFORM statements
¤ Dauer der Verarbeitung: 0.27 Sekunden
(vorverarbeitet)
¤
|
Haftungshinweis
Die Informationen auf dieser Webseite wurden
nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit,
noch Qualität der bereit gestellten Informationen zugesichert.
Bemerkung:
Die farbliche Syntaxdarstellung ist noch experimentell.
|