Quellcodebibliothek Statistik Leitseite products/sources/formale Sprachen/C/Linux/Documentation/devicetree/bindings/phy/   (Open Source Betriebssystem Version 6.17.9©)  Datei vom 24.10.2025 mit Größe 1 kB image not shown  

Quelle  phy-bindings.txt   Sprache: Text

 
This document explains only the device tree data binding. For general
information about PHY subsystem refer to Documentation/driver-api/phy/phy.rst

PHY device node
===============

Required Properties:
#phy-cells: Number of cells in a PHY specifier;  The meaning of all those
  cells is defined by the binding for the phy node. The PHY
  provider can use the values in cells to find the appropriate
  PHY.

Optional Properties:
phy-supply: Phandle to a regulator that provides power to the PHY. This
  regulator will be managed during the PHY power on/off sequence.

For example:

phys: phy {
    compatible = "xxx";
    reg = <...>;
    .
    .
    #phy-cells = <1>;
    .
    .
};

That node describes an IP block (PHY provider) that implements 2 different PHYs.
In order to differentiate between these 2 PHYs, an additional specifier should be
given while trying to get a reference to it.

PHY user node
=============

Required Properties:
phys : the phandle for the PHY device (used by the PHY subsystem; not to be
       confused with the Ethernet specific 'phy' and 'phy-handle' properties,
       see Documentation/devicetree/bindings/net/ethernet.txt for these)
phy-names : the names of the PHY corresponding to the PHYs present in the
     *phys* phandle

Example 1:
usb1: usb_otg_ss@xxx {
    compatible = "xxx";
    reg = <xxx>;
    .
    .
    phys = <&usb2_phy>, <&usb3_phy>;
    phy-names = "usb2phy", "usb3phy";
    .
    .
};

This node represents a controller that uses two PHYs, one for usb2 and one for
usb3.

Example 2:
usb2: usb_otg_ss@xxx {
    compatible = "xxx";
    reg = <xxx>;
    .
    .
    phys = <&phys 1>;
    phy-names = "usbphy";
    .
    .
};

This node represents a controller that uses one of the PHYs of the PHY provider
device defined previously. Note that the phy handle has an additional specifier
"1" to differentiate between the two PHYs.

Messung V0.5
C=94 H=97 G=95

¤ Dauer der Verarbeitung: 0.2 Sekunden  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.