/* Number of CTI signals in the v8 architecturally defined connection */ #define NR_V8PE_IN_SIGS 2 #define NR_V8PE_OUT_SIGS 3 #define NR_V8ETM_INOUT_SIGS 4
#ifdef CONFIG_OF /* * CTI can be bound to a CPU, or a system device. * CPU can be declared at the device top level or in a connections node * so need to check relative to node not device.
*/ staticint of_cti_get_cpu_at_node(conststruct device_node *node)
{ int cpu; struct device_node *dn;
if (node == NULL) return -1;
dn = of_parse_phandle(node, "cpu", 0); /* CTI affinity defaults to no cpu */ if (!dn) return -1;
cpu = of_cpu_node_to_id(dn);
of_node_put(dn);
/* No Affinity if no cpu nodes are found */ return (cpu < 0) ? -1 : cpu;
}
/* * CTI can be bound to a CPU, or a system device. * CPU can be declared at the device top level or in a connections node * so need to check relative to node not device.
*/ staticint cti_plat_get_cpu_at_node(struct fwnode_handle *fwnode)
{ if (is_of_node(fwnode)) return of_cti_get_cpu_at_node(to_of_node(fwnode)); return -1;
}
/* * Extract a name from the fwnode. * If the device associated with the node is a coresight_device, then return * that name and the coresight_device pointer, otherwise return the node name.
*/ staticconstchar *
cti_plat_get_csdev_or_node_name(struct fwnode_handle *fwnode, struct coresight_device **csdev)
{ constchar *name = NULL;
*csdev = coresight_find_csdev_by_fwnode(fwnode); if (*csdev)
name = dev_name(&(*csdev)->dev); else
name = cti_plat_get_node_name(fwnode); return name;
}
root_fwnode = dev_fwnode(dev); if (IS_ERR_OR_NULL(root_fwnode)) return -EINVAL;
/* Can optionally have an etm node - return if not */
cs_fwnode = fwnode_find_reference(root_fwnode, CTI_DT_CSDEV_ASSOC, 0); if (IS_ERR(cs_fwnode)) return 0;
/* * The EXTOUT type signals from the ETM are connected to a set of input * triggers on the CTI, the EXTIN being connected to output triggers.
*/ for (i = 0; i < NR_V8ETM_INOUT_SIGS; i++) {
tc->con_in->sig_types[i] = ETM_EXTOUT;
tc->con_out->sig_types[i] = ETM_EXTIN;
}
/* * We look to see if the ETM coresight device associated with this * handle has been registered with the system - i.e. probed before * this CTI. If so csdev will be non NULL and we can use the device * name and pass the csdev to the connection entry function where * the association will be recorded. * If not, then simply record the name in the connection data, the * probing of the ETM will call into the CTI driver API to update the * association then.
*/
assoc_name = cti_plat_get_csdev_or_node_name(cs_fwnode, &csdev);
ret = cti_add_connection_entry(dev, drvdata, tc, csdev, assoc_name);
/* * Create an architecturally defined v8 connection * must have a cpu, can have an ETM.
*/ staticint cti_plat_create_v8_connections(struct device *dev, struct cti_drvdata *drvdata)
{ struct cti_device *cti_dev = &drvdata->ctidev; struct cti_trig_con *tc = NULL; int cpuid = 0; char cpu_name_str[16]; int ret = -ENOMEM;
/* Must have a cpu node */
cpuid = cti_plat_get_cpu_at_node(dev_fwnode(dev)); if (cpuid < 0) {
dev_warn(dev, "ARM v8 architectural CTI connection: missing cpu\n"); return -EINVAL;
}
cti_dev->cpu = cpuid;
/* Allocate the v8 cpu connection memory */
tc = cti_allocate_trig_con(dev, NR_V8PE_IN_SIGS, NR_V8PE_OUT_SIGS); if (!tc) goto of_create_v8_out;
/* allocate an array according to number of signals in connection */
nr_sigs = tgrp->nr_sigs; if (!nr_sigs) return 0;
/* see if any types have been included in the device description */
items = cti_plat_count_sig_elements(fwnode, type_name); if (items > nr_sigs) return -EINVAL;
/* need an array to store the values iff there are any */ if (items) {
values = kcalloc(items, sizeof(u32), GFP_KERNEL); if (!values) return -ENOMEM;
/* * Match type id to signal index, 1st type to 1st index etc. * If fewer types than signals default remainder to GEN_IO.
*/ for (i = 0; i < nr_sigs; i++) { if (i < items) {
tgrp->sig_types[i] =
values[i] < CTI_TRIG_MAX ? values[i] : GEN_IO;
} else {
tgrp->sig_types[i] = GEN_IO;
}
}
/* look to see how many in and out signals we have */
nr_sigs_in = cti_plat_count_sig_elements(fwnode, CTI_DT_TRIGIN_SIGS);
nr_sigs_out = cti_plat_count_sig_elements(fwnode, CTI_DT_TRIGOUT_SIGS);
if ((nr_sigs_in > drvdata->config.nr_trig_max) ||
(nr_sigs_out > drvdata->config.nr_trig_max)) return -EINVAL;
tc = cti_allocate_trig_con(dev, nr_sigs_in, nr_sigs_out); if (!tc) return -ENOMEM;
/* look for the signals properties. */
err = cti_plat_read_trig_group(tc->con_in, fwnode,
CTI_DT_TRIGIN_SIGS); if (err) goto create_con_err;
err = cti_plat_read_trig_types(tc->con_in, fwnode,
CTI_DT_TRIGIN_TYPES); if (err) goto create_con_err;
err = cti_plat_read_trig_group(tc->con_out, fwnode,
CTI_DT_TRIGOUT_SIGS); if (err) goto create_con_err;
err = cti_plat_read_trig_types(tc->con_out, fwnode,
CTI_DT_TRIGOUT_TYPES); if (err) goto create_con_err;
err = cti_plat_process_filter_sigs(drvdata, fwnode); if (err) goto create_con_err;
/* read the connection name if set - may be overridden by later */
fwnode_property_read_string(fwnode, CTI_DT_CONN_NAME, &assoc_name);
if (IS_ERR_OR_NULL(dev_fwnode(dev))) return -EINVAL;
device_for_each_child_node_scoped(dev, child) { if (cti_plat_node_name_eq(child, CTI_DT_CONNS))
rc = cti_plat_create_connection(dev, drvdata, child); if (rc != 0) break;
}
return rc;
}
/* get the hardware configuration & connection data. */ staticint cti_plat_get_hw_data(struct device *dev, struct cti_drvdata *drvdata)
{ int rc = 0; struct cti_device *cti_dev = &drvdata->ctidev;
/* get any CTM ID - defaults to 0 */
device_property_read_u32(dev, CTI_DT_CTM_ID, &cti_dev->ctm_id);
/* check for a v8 architectural CTI device */ if (cti_plat_check_v8_arch_compatible(dev))
rc = cti_plat_create_v8_connections(dev, drvdata); else
rc = cti_plat_create_impdef_connections(dev, drvdata); if (rc) return rc;
/* if no connections, just add a single default based on max IN-OUT */ if (cti_dev->nr_trig_con == 0)
rc = cti_add_default_connection(dev, drvdata); return rc;
}
/* * Alloc platform data but leave it zero init. CTI does not use the * same connection infrastructuree as trace path components but an * empty struct enables us to use the standard coresight component * registration code.
*/
pdata = devm_kzalloc(dev, sizeof(*pdata), GFP_KERNEL); if (!pdata) {
ret = -ENOMEM; goto error;
}
/* get some CTI specifics */
ret = cti_plat_get_hw_data(dev, drvdata);
if (!ret) return pdata;
error: return ERR_PTR(ret);
}