IDENTIFICATION DIVISION.
PROGRAM-ID. SDL010.
ENVIRONMENT DIVISION.
CONFIGURATION SECTION.
SOURCE-COMPUTER. xyz.
OBJECT-COMPUTER. xyz.
DATA DIVISION.
WORKING-STORAGE SECTION.
* Standard COBOL (file "SDL010.SCO") calling SQL
* procedures in file "SDL010.MCO"
****************************************************************
*
* COMMENT SECTION
*
* DATE 1988/04/27 STANDARD COBOL LANGUAGE
* NIST SQL VALIDATION TEST SUITE V6.0
* DISCLAIMER:
* This program was written by employees of NIST to test SQL
* implementations for conformance to the SQL standards.
* NIST assumes no responsibility for any party's use of
* this program.
*
* SDL010.SCO
* WRITTEN BY: HU YANPING
* TRANSLATED AUTOMATICALLY FROM EMBEDDED COBOL BY CHRIS SCHANZLE
*
* THIS ROUTINE TESTS THE SCHEMA DEFINITION LANGUAGE FOR SQL.
*
* REFERENCES
* AMERICAN NATIONAL STANDARD database language - SQL
* X3.135-1989
*
* SECTION 6. Schema Definition Language
*
****************************************************************
* EXEC SQL BEGIN DECLARE SECTION END-EXEC
01 EMPNO1 PIC X(3).
01 EMPNAM PIC X(20).
01 USERID PIC X(19).
01 i PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
* EXEC SQL END DECLARE SECTION END-EXEC
01 ii PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 iii PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 uid PIC X(18).
01 uidx PIC X(18).
01 SQL-COD PIC S9(9) DISPLAY SIGN LEADING SEPARATE.
01 SQLCODE PIC S9(9) COMP.
01 errcnt PIC S9(4) DISPLAY SIGN LEADING SEPARATE.
* date_time declaration *
01 TO-DAY PIC 9(6).
01 THE-TIME PIC 9(8).
PROCEDURE DIVISION.
P0.
DISPLAY " TEST0146 "
DISPLAY " (GRANT DELETE,INSERT TO SOMEONE)"
DISPLAY " Reference X3.135-89 section 6.10 "
DISPLAY " - - - - - - - - - - - - - - - - - - -"
MOVE "SULLIVAN" TO uid
CALL "AUTHID" USING uid
MOVE "not logged in, not" TO uidx
CALL "AUTHCK" USING SQLCODE uidx
MOVE SQLCODE TO SQL-COD
if (uid NOT = uidx) then
DISPLAY "ERROR: User " uid " expected."
DISPLAY "User " uidx " connected."
DISPLAY " "
STOP RUN
END-IF
MOVE 0 TO errcnt
DISPLAY
"SQL Test Suite, V6.0, Module COBOL, sdl010.sco"
DISPLAY " "
DISPLAY
"59-byte ID"
DISPLAY "TEd Version #"
DISPLAY " "
* date_time print *
ACCEPT TO-DAY FROM DATE
ACCEPT THE-TIME FROM TIME
DISPLAY "Date run YYMMDD: " TO-DAY " at hhmmssff: " THE-TIME
* EXEC SQL INSERT INTO HU.STAFF4
* SELECT *
* FROM HU.STAFF END-EXEC
CALL "SUB1" USING SQLCODE
MOVE SQLCODE TO SQL-COD
* EXEC SQL SELECT EMPNUM,EMPNAME,USER
* INTO :EMPNO1,:EMPNAM,:USERID
* FROM HU.STAFF4
* WHERE EMPNUM = 'E3' END-EXEC
CALL "SUB2" USING SQLCODE EMPNO1 EMPNAM USERID
MOVE SQLCODE TO SQL-COD
DISPLAY " EMPNO1=", EMPNO1 ", EMPNAME=", EMPNAM ", user-id=",
USERID
* EXEC SQL INSERT INTO HU.STAFF4
* VALUES('E6','Ling',11,'Xi an') END-EXEC
CALL "SUB3" USING SQLCODE
MOVE SQLCODE TO SQL-COD
MOVE SQLCODE TO iii
* EXEC SQL SELECT EMPNUM,EMPNAME
* INTO :EMPNO1,:EMPNAM
* FROM HU.STAFF4
* WHERE EMPNUM='E6' END-EXEC
CALL "SUB4" USING SQLCODE EMPNO1 EMPNAM
MOVE SQLCODE TO SQL-COD
DISPLAY " EMPNO1=", EMPNO1 ", EMPNAME=", EMPNAM " "
COMPUTE i = -1
* EXEC SQL DELETE FROM HU.STAFF4;
CALL "SUB5" USING SQLCODE
MOVE SQLCODE TO SQL-COD
MOVE SQLCODE TO ii
* EXEC SQL SELECT COUNT(*)
* INTO :i
* FROM HU.STAFF4 END-EXEC
CALL "SUB6" USING SQLCODE i
MOVE SQLCODE TO SQL-COD
* EXEC SQL ROLLBACK WORK;
CALL "SUB7" USING SQLCODE
MOVE SQLCODE TO SQL-COD
DISPLAY " i = ", i ", ii = ", ii ", iii = ", iii " "
DISPLAY "The correct answer should be i=0,ii=0,iii=0 &
- " EMPNO1=E6"
if (iii = 0 AND ii = 0 AND i = 0 AND EMPNO1 = "E6")
then
DISPLAY " *** pass *** "
* EXEC SQL INSERT INTO HU.TESTREPORT
* VALUES('0146','pass','MCO') END-EXEC
CALL "SUB8" USING SQLCODE
MOVE SQLCODE TO SQL-COD
else
DISPLAY " sdl010.sco *** fail *** "
* EXEC SQL INSERT INTO HU.TESTREPORT
* VALUES('0146','fail','MCO') END-EXEC
ADD 1 TO errcnt
CALL "SUB9" USING SQLCODE
MOVE SQLCODE TO SQL-COD
END-IF
DISPLAY "==============================================="
* EXEC SQL COMMIT WORK;
CALL "SUB10" USING SQLCODE
MOVE SQLCODE TO SQL-COD
**** TESTER MAY CHOOSE TO INSERT CODE FOR errcnt > 0
STOP RUN.
* **** Procedures for PERFORM statements
¤ Dauer der Verarbeitung: 0.19 Sekunden
(vorverarbeitet)
¤
|
Haftungshinweis
Die Informationen auf dieser Webseite wurden
nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit,
noch Qualität der bereit gestellten Informationen zugesichert.
Bemerkung:
Die farbliche Syntaxdarstellung ist noch experimentell.
|