Quelle  omap3-thermal-data.c   Sprache: C

 
// SPDX-License-Identifier: GPL-2.0-only
/*
 * OMAP3 thermal driver.
 *
 * Copyright (C) 2011-2012 Texas Instruments Inc.
 * Copyright (C) 2014 Pavel Machek <pavel@ucw.cz>
 *
 * Note
 * http://www.ti.com/lit/er/sprz278f/sprz278f.pdf "Advisory
 * 3.1.1.186 MMC OCP Clock Not Gated When Thermal Sensor Is Used"
 *
 * Also TI says:
 * Just be careful when you try to make thermal policy like decisions
 * based on this sensor. Placement of the sensor w.r.t the actual logic
 * generating heat has to be a factor as well. If you are just looking
 * for an approximation temperature (thermometerish kind), you might be
 * ok with this. I am not sure we'd find any TI data around this.. just a
 * heads up.
 */


#include "ti-thermal.h"
#include "ti-bandgap.h"

/*
 * OMAP34XX has one instance of thermal sensor for MPU
 * need to describe the individual bit fields
 */

static struct temp_sensor_registers
omap34xx_mpu_temp_sensor_registers = {
 .temp_sensor_ctrl = 0,
 .bgap_soc_mask = BIT(8),
 .bgap_eocz_mask = BIT(7),
 .bgap_dtemp_mask = 0x7f,

 .bgap_mode_ctrl = 0,
 .mode_ctrl_mask = BIT(9),
};

/* Thresholds and limits for OMAP34XX MPU temperature sensor */
static struct temp_sensor_data omap34xx_mpu_temp_sensor_data = {
 .min_freq = 32768,
 .max_freq = 32768,
};

/*
 * Temperature values in milli degree celsius
 */

static const int
omap34xx_adc_to_temp[128] = {
 -40000, -40000, -40000, -40000, -40000, -39000, -38000, -36000,
 -34000, -32000, -31000, -29000, -28000, -26000, -25000, -24000,
 -22000, -21000, -19000, -18000, -17000, -15000, -14000, -12000,
 -11000, -9000, -8000, -7000, -5000, -4000, -2000, -1000, 0000,
 1000, 3000, 4000, 5000, 7000, 8000, 10000, 11000, 13000, 14000,
 15000, 17000, 18000, 20000, 21000, 22000, 24000, 25000, 27000,
 28000, 30000, 31000, 32000, 34000, 35000, 37000, 38000, 39000,
 41000, 42000, 44000, 45000, 47000, 48000, 49000, 51000, 52000,
 53000, 55000, 56000, 58000, 59000, 60000, 62000, 63000, 65000,
 66000, 67000, 69000, 70000, 72000, 73000, 74000, 76000, 77000,
 79000, 80000, 81000, 83000, 84000, 85000, 87000, 88000, 89000,
 91000, 92000, 94000, 95000, 96000, 98000, 99000, 100000,
 102000, 103000, 105000, 106000, 107000, 109000, 110000, 111000,
 113000, 114000, 116000, 117000, 118000, 120000, 121000, 122000,
 124000, 124000, 125000, 125000, 125000, 125000, 125000
};

/* OMAP34XX data */
const struct ti_bandgap_data omap34xx_data = {
 .features = TI_BANDGAP_FEATURE_CLK_CTRL | TI_BANDGAP_FEATURE_UNRELIABLE,
 .fclock_name = "ts_fck",
 .div_ck_name = "ts_fck",
 .conv_table = omap34xx_adc_to_temp,
 .adc_start_val = 0,
 .adc_end_val = 127,
 .expose_sensor = ti_thermal_expose_sensor,
 .remove_sensor = ti_thermal_remove_sensor,

 .sensors = {
  {
  .registers = &omap34xx_mpu_temp_sensor_registers,
  .ts_data = &omap34xx_mpu_temp_sensor_data,
  .domain = "cpu",
  .slope_pcb = 0,
  .constant_pcb = 20000,
  .register_cooling = NULL,
  .unregister_cooling = NULL,
  },
 },
 .sensor_count = 1,
};

/*
 * OMAP36XX has one instance of thermal sensor for MPU
 * need to describe the individual bit fields
 */

static struct temp_sensor_registers
omap36xx_mpu_temp_sensor_registers = {
 .temp_sensor_ctrl = 0,
 .bgap_soc_mask = BIT(9),
 .bgap_eocz_mask = BIT(8),
 .bgap_dtemp_mask = 0xFF,

 .bgap_mode_ctrl = 0,
 .mode_ctrl_mask = BIT(10),
};

/* Thresholds and limits for OMAP36XX MPU temperature sensor */
static struct temp_sensor_data omap36xx_mpu_temp_sensor_data = {
 .min_freq = 32768,
 .max_freq = 32768,
};

/*
 * Temperature values in milli degree celsius
 */

static const int
omap36xx_adc_to_temp[128] = {
 -40000, -40000, -40000, -40000, -40000, -40000, -40000, -40000,
 -40000, -40000, -40000, -40000, -40000, -38000, -35000, -34000,
 -32000, -30000, -28000, -26000, -24000, -22000, -20000, -18500,
 -17000, -15000, -13500, -12000, -10000, -8000, -6500, -5000, -3500,
 -1500, 0, 2000, 3500, 5000, 6500, 8500, 10000, 12000, 13500,
 15000, 17000, 19000, 21000, 23000, 25000, 27000, 28500, 30000,
 32000, 33500, 35000, 37000, 38500, 40000, 42000, 43500, 45000,
 47000, 48500, 50000, 52000, 53500, 55000, 57000, 58500, 60000,
 62000, 64000, 66000, 68000, 70000, 71500, 73500, 75000, 77000,
 78500, 80000, 82000, 83500, 85000, 87000, 88500, 90000, 92000,
 93500, 95000, 97000, 98500, 100000, 102000, 103500, 105000, 107000,
 109000, 111000, 113000, 115000, 117000, 118500, 120000, 122000,
 123500, 125000, 125000, 125000, 125000, 125000, 125000, 125000,
 125000, 125000, 125000, 125000, 125000, 125000, 125000, 125000,
 125000, 125000, 125000, 125000, 125000, 125000, 125000
};

/* OMAP36XX data */
const struct ti_bandgap_data omap36xx_data = {
 .features = TI_BANDGAP_FEATURE_CLK_CTRL | TI_BANDGAP_FEATURE_UNRELIABLE,
 .fclock_name = "ts_fck",
 .div_ck_name = "ts_fck",
 .conv_table = omap36xx_adc_to_temp,
 .adc_start_val = 0,
 .adc_end_val = 127,
 .expose_sensor = ti_thermal_expose_sensor,
 .remove_sensor = ti_thermal_remove_sensor,

 .sensors = {
  {
  .registers = &omap36xx_mpu_temp_sensor_registers,
  .ts_data = &omap36xx_mpu_temp_sensor_data,
  .domain = "cpu",
  .slope_pcb = 0,
  .constant_pcb = 20000,
  .register_cooling = NULL,
  .unregister_cooling = NULL,
  },
 },
 .sensor_count = 1,
};

Messung V0.5
C=90 H=100 G=95

¤ Dauer der Verarbeitung: 0.0 Sekunden  (vorverarbeitet)  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.