000100 IDENTIFICATION DIVISION . IC2064.2
000200 PROGRAM-ID . IC2064.2
000300 IC206A. IC2064.2
000400**************************************************************** IC2064.2
000500* * IC2064.2
000600* VALIDATION FOR:- * IC2064.2
000700* * IC2064.2
000800* "ON-SITE VALIDATION, NATIONAL INSTITUTE OF STD & TECH. ".IC2064.2
000900* * IC2064.2
001000* "COBOL 85 VERSION 4.2, Apr 1993 SSVG ".IC2064.2
001100* * IC2064.2
001200**************************************************************** IC2064.2
001300* * IC2064.2
001400* X-CARDS USED BY THIS PROGRAM ARE :- * IC2064.2
001500* * IC2064.2
001600* X-55 - SYSTEM PRINTER NAME. * IC2064.2
001700* X-82 - SOURCE COMPUTER NAME. * IC2064.2
001800* X-83 - OBJECT COMPUTER NAME. * IC2064.2
001900* * IC2064.2
002000**************************************************************** IC2064.2
002100* THE SUBPROGRAM IC206 IS CALLED BY THE SUBPROGRAM IC2064.2
002200* IC205. THE SUBPROGRAM IS THEN CANCELED AND CALLED IC2064.2
002300* AGAIN. THE PROGRAM IC205 CHECKS IF IC206 WAS IN ITS IC2064.2
002400* INITIAL STATE ON THE FIRST CALL AFTER THE PROGRAM WAS IC2064.2
002500* CANCELED. IC2064.2
002600* THE LINKAGE PARAMETER DN1 CONTAINS THE NUMBER OF IC2064.2
002700* TIMES IC206 HAS BEEN CALLED SINCE INITIALIZATION WHEN IC2064.2
002800* CONTROL IS RETURNED TO THE CALLING PROGRAM. IC2064.2
002900**************************************************************** IC2064.2
003000 ENVIRONMENT DIVISION . IC2064.2
003100 CONFIGURATION SECTION . IC2064.2
003200 SOURCE-COMPUTER . IC2064.2
003300 Card0130. IC2064.2
003400 OBJECT-COMPUTER . IC2064.2
003500 Card0131. IC2064.2
003600 INPUT-OUTPUT SECTION . IC2064.2
003700 FILE-CONTROL . IC2064.2
003800 SELECT PRINT-FILE ASSIGN TO IC2064.2
003900 "C0085" . IC2064.2
004000 DATA DIVISION . IC2064.2
004100 FILE SECTION . IC2064.2
004200 FD PRINT-FILE. IC2064.2
004300 01 PRINT-REC PICTURE X(120). IC2064.2
004400 01 DUMMY-RECORD PICTURE X(120). IC2064.2
004500 WORKING-STORAGE SECTION . IC2064.2
004600 77 WS1 PICTURE S9(8) USAGE COMPUTATIONAL IC2064.2
004700 VALUE ZERO . IC2064.2
004800 LINKAGE SECTION . IC2064.2
004900 01 DN1 PICTURE S9(8) USAGE COMPUTATIONAL. IC2064.2
005000 PROCEDURE DIVISION USING DN1. IC2064.2
005100 SECT-IC206-0001 SECTION . IC2064.2
005200 TEST-PARAGRAPH. IC2064.2
005300 ADD 1 TO WS1. IC2064.2
005400 MOVE WS1 TO DN1. IC2064.2
005500 EXIT-IC206. IC2064.2
005600 EXIT PROGRAM . IC2064.2
Messung V0.5 C=73 H=100 G=87
¤ Dauer der Verarbeitung: 0.14 Sekunden
(vorverarbeitet)
¤
*© Formatika GbR, Deutschland