Quelle  sysfs-bus-iio-adc-hi8435   Sprache: C

 
What:  /sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
Date:  August 2015
KernelVersion: 4.2.0
Contact: source@cogentembedded.com
Description:
  Program sensor type for threshold detector inputs.
  Could be either "GND-Open" or "Supply-Open" mode. Y is a
  threshold detector input channel. Channels 0..7, 8..15, 16..23
  and 24..31 has common sensor types.

What:  /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
Date:  August 2015
KernelVersion: 4.2.0
Contact: source@cogentembedded.com
Description:
  Channel Y low voltage threshold. If sensor input voltage goes lower then
  this value then the threshold falling event is pushed.
  Depending on in_voltageY_sensing_mode the low voltage threshold
  is separately set for "GND-Open" and "Supply-Open" modes.
  Channels 0..31 have common low threshold values, but could have different
  sensing_modes.

  The low voltage threshold range is between 2..21V.
  Hysteresis between low and high thresholds can not be lower then 2 and
  can not be odd.

  If falling threshold results hysteresis to odd value then rising
  threshold is automatically subtracted by one.

What:  /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
Date:  August 2015
KernelVersion: 4.2.0
Contact: source@cogentembedded.com
Description:
  Channel Y high voltage threshold. If sensor input voltage goes higher then
  this value then the threshold rising event is pushed.
  Depending on in_voltageY_sensing_mode the high voltage threshold
  is separately set for "GND-Open" and "Supply-Open" modes.

  Channels 0..31 have common high threshold values, but could have different
  sensing_modes.

  The high voltage threshold range is between 3..22V.
  Hysteresis between low and high thresholds can not be lower then 2 and
  can not be odd.

  If rising threshold results hysteresis to odd value then falling
  threshold is automatically appended by one.

¤ Dauer der Verarbeitung: 0.1 Sekunden  (vorverarbeitet)  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.