Eine aufbereitete Darstellung der Quelle

 
     
 
 
Anforderungen  |   Konzepte  |   Entwurf  |   Entwicklung  |   Qualitätssicherung  |   Lebenszyklus  |   Steuerung
 
 
 
 

Benutzer

SSL charger-manager.h  Interaktion und
Portierbarkeitunbekannt

 
rahmenlose Ansicht.h DruckansichtAbap {ABAP[40] Fortran[36] Hlasm[34]}Mathematik

/* SPDX-License-Identifier: GPL-2.0-only */
/*
 * Copyright (C) 2011 Samsung Electronics Co., Ltd.
 * MyungJoo.Ham <myungjoo.ham@samsung.com>
 *
 * Charger Manager.
 * This framework enables to control and multiple chargers and to
 * monitor charging even in the context of suspend-to-RAM with
 * an interface combining the chargers.
 *
**/

#ifndef _CHARGER_MANAGER_H
#define _CHARGER_MANAGER_H

#include <linux/power_supply.h>
#include <linux/extcon.h>
#include <linux/alarmtimer.h>

enum data_source {
 CM_BATTERY_PRESENT,
 CM_NO_BATTERY,
 CM_FUEL_GAUGE,
 CM_CHARGER_STAT,
};

enum polling_modes {
 CM_POLL_DISABLE = 0,
 CM_POLL_ALWAYS,
 CM_POLL_EXTERNAL_POWER_ONLY,
 CM_POLL_CHARGING_ONLY,
};

enum cm_batt_temp {
 CM_BATT_OK = 0,
 CM_BATT_OVERHEAT,
 CM_BATT_COLD,
};

/**
 * struct charger_cable
 * @extcon_name: the name of extcon device.
 * @name: the name of the cable connector
 * @extcon_dev: the extcon device.
 * @wq: the workqueue to control charger according to the state of
 * charger cable. If charger cable is attached, enable charger.
 * But if charger cable is detached, disable charger.
 * @nb: the notifier block to receive changed state from EXTCON
 * (External Connector) when charger cable is attached/detached.
 * @attached: the state of charger cable.
 * true: the charger cable is attached
 * false: the charger cable is detached
 * @charger: the instance of struct charger_regulator.
 * @cm: the Charger Manager representing the battery.
 */

struct charger_cable {
 const char *extcon_name;
 const char *name;
 struct extcon_dev *extcon_dev;
 u64 extcon_type;

 /* The charger-manager use Extcon framework */
 struct work_struct wq;
 struct notifier_block nb;

 /* The state of charger cable */
 bool attached;

 struct charger_regulator *charger;

 /*
  * Set min/max current of regulator to protect over-current issue
  * according to a kind of charger cable when cable is attached.
 */

 int min_uA;
 int max_uA;

 struct charger_manager *cm;
};

/**
 * struct charger_regulator
 * @regulator_name: the name of regulator for using charger.
 * @consumer: the regulator consumer for the charger.
 * @externally_control:
 * Set if the charger-manager cannot control charger,
 * the charger will be maintained with disabled state.
 * @cables:
 * the array of charger cables to enable/disable charger
 * and set current limit according to constraint data of
 * struct charger_cable if only charger cable included
 * in the array of charger cables is attached/detached.
 * @num_cables: the number of charger cables.
 * @attr_g: Attribute group for the charger(regulator)
 * @attr_name: "name" sysfs entry
 * @attr_state: "state" sysfs entry
 * @attr_externally_control: "externally_control" sysfs entry
 * @attrs: Arrays pointing to attr_name/state/externally_control for attr_g
 */

struct charger_regulator {
 /* The name of regulator for charging */
 const char *regulator_name;
 struct regulator *consumer;

 /* charger never on when system is on */
 int externally_control;

 /*
  * Store constraint information related to current limit,
  * each cable have different condition for charging.
 */

 struct charger_cable *cables;
 int num_cables;

 struct attribute_group attr_grp;
 struct device_attribute attr_name;
 struct device_attribute attr_state;
 struct device_attribute attr_externally_control;
 struct attribute *attrs[4];

 struct charger_manager *cm;
};

/**
 * struct charger_desc
 * @psy_name: the name of power-supply-class for charger manager
 * @polling_mode:
 * Determine which polling mode will be used
 * @fullbatt_vchkdrop_uV:
 * Check voltage drop after the battery is fully charged.
 * If it has dropped more than fullbatt_vchkdrop_uV
 * CM will restart charging.
 * @fullbatt_uV: voltage in microvolt
 * If VBATT >= fullbatt_uV, it is assumed to be full.
 * @fullbatt_soc: state of Charge in %
 * If state of Charge >= fullbatt_soc, it is assumed to be full.
 * @fullbatt_full_capacity: full capacity measure
 * If full capacity of battery >= fullbatt_full_capacity,
 * it is assumed to be full.
 * @polling_interval_ms: interval in millisecond at which
 * charger manager will monitor battery health
 * @battery_present:
 * Specify where information for existence of battery can be obtained
 * @psy_charger_stat: the names of power-supply for chargers
 * @num_charger_regulator: the number of entries in charger_regulators
 * @charger_regulators: array of charger regulators
 * @psy_fuel_gauge: the name of power-supply for fuel gauge
 * @thermal_zone : the name of thermal zone for battery
 * @temp_min : Minimum battery temperature for charging.
 * @temp_max : Maximum battery temperature for charging.
 * @temp_diff : Temperature difference to restart charging.
 * @measure_battery_temp:
 * true: measure battery temperature
 * false: measure ambient temperature
 * @charging_max_duration_ms: Maximum possible duration for charging
 * If whole charging duration exceed 'charging_max_duration_ms',
 * cm stop charging.
 * @discharging_max_duration_ms:
 * Maximum possible duration for discharging with charger cable
 * after full-batt. If discharging duration exceed 'discharging
 * max_duration_ms', cm start charging.
 */

struct charger_desc {
 const char *psy_name;

 enum polling_modes polling_mode;
 unsigned int polling_interval_ms;

 unsigned int fullbatt_vchkdrop_uV;
 unsigned int fullbatt_uV;
 unsigned int fullbatt_soc;
 unsigned int fullbatt_full_capacity;

 enum data_source battery_present;

 const char **psy_charger_stat;

 int num_charger_regulators;
 struct charger_regulator *charger_regulators;
 const struct attribute_group **sysfs_groups;

 const char *psy_fuel_gauge;

 const char *thermal_zone;

 int temp_min;
 int temp_max;
 int temp_diff;

 bool measure_battery_temp;

 u32 charging_max_duration_ms;
 u32 discharging_max_duration_ms;
};

#define PSY_NAME_MAX 30

/**
 * struct charger_manager
 * @entry: entry for list
 * @dev: device pointer
 * @desc: instance of charger_desc
 * @fuel_gauge: power_supply for fuel gauge
 * @charger_stat: array of power_supply for chargers
 * @tzd_batt : thermal zone device for battery
 * @charger_enabled: the state of charger
 * @emergency_stop:
 * When setting true, stop charging
 * @psy_name_buf: the name of power-supply-class for charger manager
 * @charger_psy: power_supply for charger manager
 * @status_save_ext_pwr_inserted:
 * saved status of external power before entering suspend-to-RAM
 * @status_save_batt:
 * saved status of battery before entering suspend-to-RAM
 * @charging_start_time: saved start time of enabling charging
 * @charging_end_time: saved end time of disabling charging
 * @battery_status: Current battery status
 */

struct charger_manager {
 struct list_head entry;
 struct device *dev;
 struct charger_desc *desc;

#ifdef CONFIG_THERMAL
 struct thermal_zone_device *tzd_batt;
#endif
 bool charger_enabled;

 int emergency_stop;

 char psy_name_buf[PSY_NAME_MAX + 1];
 struct power_supply_desc charger_psy_desc;
 struct power_supply *charger_psy;

 u64 charging_start_time;
 u64 charging_end_time;

 int battery_status;
};

#endif /* _CHARGER_MANAGER_H */

[Verzeichnis aufwärts0.8unsichere Verbindung]

                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Open Source Software

     Quellcodebibliothek
     Eigene Quellcodes
     Fremde Quellcodes
     Suchen

Jenseits des Üblichen ....

Besucherstatistik

Besucherstatistik

Statistik
#Sources=1127926
#Domains=2039723