What:  /sys/bus/iio/devices/triggerX/trigger_polarity
KernelVersion: 4.11
Contact: fabrice.gasnier@st.com
Description:
  The STM32 ADC can be configured to use external trigger sources
  (e.g. timers, pwm or exti gpio). Then, it can be tuned to start
  conversions on external trigger by either:

  - "rising-edge"
  - "falling-edge"
  - "both-edges".

  Reading returns current trigger polarity.

  Writing value before enabling conversions sets trigger polarity.

What:  /sys/bus/iio/devices/triggerX/trigger_polarity_available
KernelVersion: 4.11
Contact: fabrice.gasnier@st.com
Description:
  List all available trigger_polarity settings.