Quelle  sysfs-bus-iio-thermocouple   Sprache: unbekannt

 
What:  /sys/bus/iio/devices/iio:deviceX/fault_ovuv
KernelVersion: 5.1
Contact: linux-iio@vger.kernel.org
Description:
  Overvoltage or Undervoltage Input Fault. The internal circuitry
  is protected from excessive voltages applied to the thermocouple
  cables. The device can also detect if such a condition occurs.

  Reading returns '1' if input voltage is negative or greater
  than VDD, otherwise '0'.

What:  /sys/bus/iio/devices/iio:deviceX/fault_oc
KernelVersion: 5.1
Contact: linux-iio@vger.kernel.org
Description:
  Open-circuit fault. The detection of open-circuit faults,
  such as those caused by broken thermocouple wires.
  Reading returns '1' if fault, '0' otherwise.