Anforderungen  |   Konzepte  |   Entwurf  |   Entwicklung  |   Qualitätssicherung  |   Lebenszyklus  |   Steuerung
 
 
 
 


Quelle  pwm-amlogic.yaml   Sprache: unbekannt

 
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
%YAML 1.2
---
$id: http://devicetree.org/schemas/pwm/pwm-amlogic.yaml#
$schema: http://devicetree.org/meta-schemas/core.yaml#

title: Amlogic PWM

maintainers:
  - Heiner Kallweit <hkallweit1@gmail.com>

properties:
  compatible:
    oneOf:
      - enum:
          - amlogic,meson8b-pwm
          - amlogic,meson-gxbb-pwm
          - amlogic,meson-gxbb-ao-pwm
          - amlogic,meson-axg-ee-pwm
          - amlogic,meson-axg-ao-pwm
          - amlogic,meson-g12a-ee-pwm
          - amlogic,meson-g12a-ao-pwm-ab
          - amlogic,meson-g12a-ao-pwm-cd
        deprecated: true
      - items:
          - const: amlogic,meson-gx-pwm
          - const: amlogic,meson-gxbb-pwm
        deprecated: true
      - items:
          - const: amlogic,meson-gx-ao-pwm
          - const: amlogic,meson-gxbb-ao-pwm
        deprecated: true
      - items:
          - const: amlogic,meson8-pwm
          - const: amlogic,meson8b-pwm
        deprecated: true
      - enum:
          - amlogic,meson8-pwm-v2
          - amlogic,meson-s4-pwm
      - items:
          - enum:
              - amlogic,c3-pwm
              - amlogic,meson-a1-pwm
          - const: amlogic,meson-s4-pwm
      - items:
          - enum:
              - amlogic,meson8b-pwm-v2
              - amlogic,meson-gxbb-pwm-v2
              - amlogic,meson-axg-pwm-v2
              - amlogic,meson-g12-pwm-v2
          - const: amlogic,meson8-pwm-v2

  reg:
    maxItems: 1

  clocks:
    minItems: 1
    maxItems: 4

  clock-names:
    minItems: 1
    maxItems: 2

  power-domains:
    maxItems: 1

  "#pwm-cells":
    const: 3

required:
  - compatible
  - reg

allOf:
  - $ref: pwm.yaml#

  - if:
      properties:
        compatible:
          contains:
            enum:
              - amlogic,meson8-pwm
              - amlogic,meson8b-pwm
              - amlogic,meson-gxbb-pwm
              - amlogic,meson-gxbb-ao-pwm
              - amlogic,meson-axg-ee-pwm
              - amlogic,meson-axg-ao-pwm
              - amlogic,meson-g12a-ee-pwm
              - amlogic,meson-g12a-ao-pwm-ab
              - amlogic,meson-g12a-ao-pwm-cd
    then:
      # Obsolete historic bindings tied to the driver implementation
      # The clocks provided here are meant to be matched with the input
      # known (hard-coded) in the driver and used to select pwm clock
      # source. Currently, the linux driver ignores this.
      # This is kept to maintain ABI backward compatibility.
      properties:
        clocks:
          maxItems: 2
        clock-names:
          oneOf:
            - items:
                - enum: [clkin0, clkin1]
            - items:
                - const: clkin0
                - const: clkin1

  # Newer binding where clock describe the actual clock inputs of the pwm
  # block. These are necessary but some inputs may be grounded.
  - if:
      properties:
        compatible:
          contains:
            enum:
              - amlogic,meson8-pwm-v2
    then:
      properties:
        clocks:
          minItems: 1
          items:
            - description: input clock 0 of the pwm block
            - description: input clock 1 of the pwm block
            - description: input clock 2 of the pwm block
            - description: input clock 3 of the pwm block
        clock-names: false
      required:
        - clocks

  # Newer IP block take a single input per channel, instead of 4 inputs
  # for both channels
  - if:
      properties:
        compatible:
          contains:
            enum:
              - amlogic,meson-s4-pwm
    then:
      properties:
        clocks:
          items:
            - description: input clock of PWM channel A
            - description: input clock of PWM channel B
        clock-names: false
      required:
        - clocks

  - if:
      properties:
        compatible:
          contains:
            enum:
              - amlogic,meson-a1-pwm
    then:
      required:
        - power-domains

additionalProperties: false

examples:
  - |
    pwm@8550 {
      compatible = "amlogic,meson-gxbb-pwm";
      reg = <0x08550 0x10>;
      clocks = <&xtal>, <&xtal>;
      clock-names = "clkin0", "clkin1";
      #pwm-cells = <3>;
    };
  - |
    pwm@2000 {
      compatible = "amlogic,meson8-pwm-v2";
      reg = <0x1000 0x10>;
      clocks = <&xtal>, <0>, <&fdiv4>, <&fdiv5>;
      #pwm-cells = <3>;
    };
  - |
    pwm@1000 {
      compatible = "amlogic,meson-s4-pwm";
      reg = <0x1000 0x10>;
      clocks = <&pwm_src_a>, <&pwm_src_b>;
      #pwm-cells = <3>;
    };

[ Dauer der Verarbeitung: 0.13 Sekunden  (vorverarbeitet)  ]

                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....
    

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge