Quelle  sbrmi.rst   Sprache: unbekannt

 
.. SPDX-License-Identifier: GPL-2.0-or-later

Kernel driver sbrmi
===================

Supported hardware:

  * Sideband Remote Management Interface (SB-RMI) compliant AMD SoC
    device connected to the BMC via the APML.

    Prefix: 'sbrmi'

    Addresses scanned: This driver doesn't support address scanning.

    To instantiate this driver on an AMD CPU with SB-RMI
    support, the i2c bus number would be the bus connected from the board
    management controller (BMC) to the CPU.
    The SMBus address is really 7 bits. Some vendors and the SMBus
    specification show the address as 8 bits, left justified with the R/W
    bit as a write (0) making bit 0. Some vendors use only the 7 bits
    to describe the address.
    As mentioned in AMD's APML specification, The SB-RMI address is
    normally 78h(0111 100W) or 3Ch(011 1100) for socket 0 and 70h(0111 000W)
    or 38h(011 1000) for socket 1, but it could vary based on hardware
    address select pins.

    Datasheet: The SB-RMI interface and protocol along with the Advanced
               Platform Management Link (APML) Specification is available
               as part of the open source SoC register reference at:

               https://www.amd.com/en/support/tech-docs?keyword=55898

Author: Akshay Gupta <akshay.gupta@amd.com>

Description
-----------

The APML provides a way to communicate with the SB Remote Management interface
(SB-RMI) module from the external SMBus master that can be used to report socket
power on AMD platforms using mailbox command and resembles a typical 8-pin remote
power sensor's I2C interface to BMC.

This driver implements current power with power cap and power cap max.

sysfs-Interface
---------------
Power sensors can be queried and set via the standard ``hwmon`` interface
on ``sysfs``, under the directory ``/sys/class/hwmon/hwmonX`` for some value
of ``X`` (search for the ``X`` such that ``/sys/class/hwmon/hwmonX/name`` has
content ``sbrmi``)

================ ===== ========================================================
Name             Perm   Description
================ ===== ========================================================
power1_input     RO    Current Power consumed
power1_cap       RW    Power limit can be set between 0 and power1_cap_max
power1_cap_max   RO    Maximum powerlimit calculated and reported by the SMU FW
================ ===== ========================================================

The following example show how the 'Power' attribute from the i2c-addresses
can be monitored using the userspace utilities like ``sensors`` binary::

  # sensors
  sbrmi-i2c-1-38
  Adapter: bcm2835 I2C adapter
  power1:       61.00 W (cap = 225.00 W)

  sbrmi-i2c-1-3c
  Adapter: bcm2835 I2C adapter
  power1:       28.39 W (cap = 224.77 W)
  #

Also, Below shows how get and set the values from sysfs entries individually::
  # cat /sys/class/hwmon/hwmon1/power1_cap_max
  225000000

  # echo 180000000 > /sys/class/hwmon/hwmon1/power1_cap
  # cat /sys/class/hwmon/hwmon1/power1_cap
  180000000

[ Dauer der Verarbeitung: 0.2 Sekunden  (vorverarbeitet)  ]

                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge