Anforderungen  |   Konzepte  |   Entwurf  |   Entwicklung  |   Qualitätssicherung  |   Lebenszyklus  |   Steuerung
 
 
 
 


Quelle  hp6xx_apm.c   Sprache: C

 
// SPDX-License-Identifier: GPL-2.0
/*
 * bios-less APM driver for hp680
 *
 * Copyright 2005 (c) Andriy Skulysh <askulysh@gmail.com>
 * Copyright 2008 (c) Kristoffer Ericson <kristoffer.ericson@gmail.com>
 */

#include <linux/module.h>
#include <linux/kernel.h>
#include <linux/init.h>
#include <linux/interrupt.h>
#include <linux/apm-emulation.h>
#include <linux/io.h>
#include <asm/adc.h>
#include <mach/hp6xx.h>

/* percentage values */
#define APM_CRITICAL   10
#define APM_LOW    30

/* resonably sane values */
#define HP680_BATTERY_MAX  898
#define HP680_BATTERY_MIN  486
#define HP680_BATTERY_AC_ON  1023

#define MODNAME "hp6x0_apm"

#define PGDR 0xa400012c

static void hp6x0_apm_get_power_status(struct apm_power_info *info)
{
 int battery, backup, charging, percentage;
 u8 pgdr;

 battery  = adc_single(ADC_CHANNEL_BATTERY);
 backup  = adc_single(ADC_CHANNEL_BACKUP);
 charging = adc_single(ADC_CHANNEL_CHARGE);

 percentage = 100 * (battery - HP680_BATTERY_MIN) /
      (HP680_BATTERY_MAX - HP680_BATTERY_MIN);

 /* % of full battery */
 info->battery_life = percentage;

 /* We want our estimates in minutes */
 info->units = 0;

 /* Extremely(!!) rough estimate, we will replace this with a datalist later on */
 info->time = (2 * battery);

 info->ac_line_status = (battery > HP680_BATTERY_AC_ON) ?
    APM_AC_ONLINE : APM_AC_OFFLINE;

 pgdr = __raw_readb(PGDR);
 if (pgdr & PGDR_MAIN_BATTERY_OUT) {
  info->battery_status = APM_BATTERY_STATUS_NOT_PRESENT;
  info->battery_flag = 0x80;
 } else if (charging < 8) {
  info->battery_status = APM_BATTERY_STATUS_CHARGING;
  info->battery_flag = 0x08;
  info->ac_line_status = 0x01;
 } else if (percentage <= APM_CRITICAL) {
  info->battery_status = APM_BATTERY_STATUS_CRITICAL;
  info->battery_flag = 0x04;
 } else if (percentage <= APM_LOW) {
  info->battery_status = APM_BATTERY_STATUS_LOW;
  info->battery_flag = 0x02;
 } else {
  info->battery_status = APM_BATTERY_STATUS_HIGH;
  info->battery_flag = 0x01;
 }
}

static irqreturn_t hp6x0_apm_interrupt(int irq, void *dev)
{
 if (!APM_DISABLED)
  apm_queue_event(APM_USER_SUSPEND);

 return IRQ_HANDLED;
}

static int __init hp6x0_apm_init(void)
{
 int ret;

 ret = request_irq(HP680_BTN_IRQ, hp6x0_apm_interrupt,
     0, MODNAME, NULL);
 if (unlikely(ret < 0)) {
  printk(KERN_ERR MODNAME ": IRQ %d request failed\n",
         HP680_BTN_IRQ);
  return ret;
 }

 apm_get_power_status = hp6x0_apm_get_power_status;

 return ret;
}

static void __exit hp6x0_apm_exit(void)
{
 free_irq(HP680_BTN_IRQ, 0);
}

module_init(hp6x0_apm_init);
module_exit(hp6x0_apm_exit);

MODULE_AUTHOR("Adriy Skulysh");
MODULE_DESCRIPTION("hp6xx Advanced Power Management");
MODULE_LICENSE("GPL");

Messung V0.5
C=96 H=90 G=93

¤ Dauer der Verarbeitung: 0.3 Sekunden  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.






                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge