Anforderungen  |   Konzepte  |   Entwurf  |   Entwicklung  |   Qualitätssicherung  |   Lebenszyklus  |   Steuerung
 
 
 
 


Quelle  chgpco.ted   Sprache: unbekannt

 
! ----------------------------------------------------------------------
!                     IDENTIFICATION SECTION                  
!                        Embedded COBOL
! ----------------------------------------------------------------------
!
sub *.* /59-byte ID/
/59-byte ID/___________________________________________________________/
!
! Document version of TEd used, for audit purposes.
!
sub *.* /TEd Version #/ -m
"TEd Version #"TEd Version $ver"
!
!
! ----------------------------------------------------------------------
!                     MAINTENANCE SECTION                  
! ----------------------------------------------------------------------
!
! Use the  -t  option on TEd to apply the official maintenance file.
! Then use a second  -t  option on TEd to apply this file.
!      OR     
! Insert the entire maintenance file in this position.
!
! ----------------------------------------------------------------------
!                     LOGIN SECTION                  
! ----------------------------------------------------------------------
!
! The login problem is solved here:
! If passwords are system-login passwords, then no changes are necessary.
! For other implementations, changes may be needed.
!
! The call to AUTHID may be replaced with some implementor-defined syntax.
! For example, you may choose to code:
! rep *.pco /CALL "AUTHID"/
!            EXEC SQL CONNECT :uid IDENTIFIED BY :uid END-EXEC
!
! Other changes to establish the ANSI-standard environment would be coded here.
!
!
! ----------------------------------------------------------------------
!                     IMPLEMENTOR-DEFINED SECTION                  
! ----------------------------------------------------------------------
!
! Install implementor-defined precision of SQLCODE
! For example, to change precision from 9 to 4, code:
!            sub *.pco /SQLCODE/
!            /S9(9)/S9(4)/
!
! Install implementor-defined data type for indicator variable
! For example, to change data type to COMP, code:
!            sub *.pco /indic/
!            /DISPLAY SIGN LEADING SEPARATE/COMP/
!
! Modify dml063 to declare vendor-reserved key words
! For example, to declare UPDATE a vendor-reserved key word, code: 
!            del *dml063.pco /01  UPDATE /
!            del *dml063.pco /:UPDATE/MOVE UPDATE TO/
!
!
! Install vendor-supplied extensions to demonstrate FIPS Flagging:
! (Replace the underscores with vendor-supplied extensions.)
!
sub *{flg005,xop709}.pco //
/SUBSTR(EMPNAME,1,3) = 'Ali'/____________________/
/ABS(GRADE) = 12/________________/
!
! Change 18-character AUTHORIZATION ID to max supported in this DBMS/OS:
!            sub *.* /CANWEPARSELENGTH18/
!            /CANWEPARSELENGTH18/WECANPARSE12/
!
! Change COBOL programs to specify correct source and object computers
sub *.[ps]co /COMPUTER/
/xyz/_______________/
!
! ----------------------------------------------------------------------
!                     APPROVED CHANGES SECTION
! ----------------------------------------------------------------------
!
! Include here any changes approved by NIST for this validation:
!
! For example, to lengthen concurrency test #0230 (according to documentation),
!   to allow interleaving for a DBMS using "burst" mode CPU allocation:
!            sub *mp?001.[ps]* /keymax/ -i
!            /50/300/
!
!
! ----------------------------------------------------------------------
!                     SYNTAX DEFICIENCIES SECTION                  
! ----------------------------------------------------------------------
!
!
! If a program cannot be executed because the precompiler issues 
!   a fatal syntax error message for a minor deficiency which is not
!   the purpose of the test case, propose a change to NIST.  
! A syntax change should be made to allow an SQL implementation 
!   to demonstrate functionality, i.e. semantic conformance.
! A global change will be counted as a single deficiency.
!  
! ----------------------------------------------------------------------
!                     DELETED TESTS SECTION                  
! ----------------------------------------------------------------------
!
! If a program cannot be executed because the precompiler issues
!   a fatal syntax error message for one of the tests, either propose a
!   change to NIST or delete the entire test so that the rest of the tests
!   in the program may execute.  If this test is required, and not a FIPS
!   Flagger test, it will appear as a deficiency on REPORT 4.
! For COBOL, a performed paragraph is found at the end of the program.
!   So a separate delete command is needed for a performed paragraph.
!
! For example, to remove test number 278, code
!            del *dml061.pco /BEGIN TEST0278/END TEST0278/
!
!

[ Dauer der Verarbeitung: 0.20 Sekunden  (vorverarbeitet)  ]

                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge