What:           /sys/devices/uncore_iio_x/dieX
Date:           February 2020
Contact:        Alexander Antonov <alexander.antonov@linux.intel.com>
Description:
                Each IIO stack (PCIe root port) has its own IIO PMON block, so
                each dieX file (where X is die number) holds "Segment:Root Bus"
                for PCIe root port, which can be monitored by that IIO PMON
                block.
                For example, on 4-die Xeon platform with up to 6 IIO stacks per
                die and, therefore, 6 IIO PMON blocks per die, the mapping of
                IIO PMON block 0 exposes as the following::

      $ ls /sys/devices/uncore_iio_0/die*
      -r--r--r-- /sys/devices/uncore_iio_0/die0
      -r--r--r-- /sys/devices/uncore_iio_0/die1
      -r--r--r-- /sys/devices/uncore_iio_0/die2
      -r--r--r-- /sys/devices/uncore_iio_0/die3

      $ tail /sys/devices/uncore_iio_0/die*
      ==> /sys/devices/uncore_iio_0/die0 <==
      0000:00
      ==> /sys/devices/uncore_iio_0/die1 <==
      0000:40
      ==> /sys/devices/uncore_iio_0/die2 <==
      0000:80
      ==> /sys/devices/uncore_iio_0/die3 <==
      0000:c0

                Which means::

      IIO PMU 0 on die 0 belongs to PCI RP on bus 0x00, domain 0x0000
      IIO PMU 0 on die 1 belongs to PCI RP on bus 0x40, domain 0x0000
      IIO PMU 0 on die 2 belongs to PCI RP on bus 0x80, domain 0x0000
      IIO PMU 0 on die 3 belongs to PCI RP on bus 0xc0, domain 0x0000

What:           /sys/devices/uncore_upi_x/dieX
Date:           March 2022
Contact:        Alexander Antonov <alexander.antonov@linux.intel.com>
Description:
                Each /sys/devices/uncore_upi_X/dieY file holds "upi_Z,die_W"
                value that means UPI link number X on die Y is connected to UPI
                link Z on die W and this link between sockets can be monitored
                by UPI PMON block.
                For example, 4-die Sapphire Rapids platform has the following
                UPI 0 topology::

      tail /sys/devices/uncore_upi_0/die*
      ==> /sys/devices/uncore_upi_0/die0 <==
      upi_1,die_1
      ==> /sys/devices/uncore_upi_0/die1 <==
      upi_0,die_3
      ==> /sys/devices/uncore_upi_0/die2 <==
      upi_1,die_3
      ==> /sys/devices/uncore_upi_0/die3 <==
      upi_0,die_1

                Which means::

      UPI link 0 on die 0 is connected to UPI link 1 on die 1
      UPI link 0 on die 1 is connected to UPI link 0 on die 3
      UPI link 0 on die 2 is connected to UPI link 1 on die 3
      UPI link 0 on die 3 is connected to UPI link 0 on die 1

Messung V0.5
C=92 H=92 G=91

¤ Dauer der Verarbeitung: 0.11 Sekunden  (vorverarbeitet)  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.






                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....
    

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge