Anforderungen  |   Konzepte  |   Entwurf  |   Entwicklung  |   Qualitätssicherung  |   Lebenszyklus  |   Steuerung
 
 
 
 


Quelle  sysfs-firmware-sgi_uv   Sprache: C

 
What:  /sys/firmware/sgi_uv/
Date:  September 2020
Contact: Justin Ernst <justin.ernst@hpe.com>
Description:
  The /sys/firmware/sgi_uv directory contains information
  about the UV platform.

  Under that directory are a number of read-only attributes::

   archtype
   hub_type
   hubless
   partition_id
   coherence_id
   uv_type

  The archtype entry contains the UV architecture type that
  is used to select arch-dependent addresses and features.
  It can be set via the OEM_ID in the ACPI MADT table or by
  UVsystab entry both passed from UV BIOS.

  The hub_type entry is used to select the type of hub which is
  similar to uv_type but encoded in a binary format.  Include
  the file uv_hub.h to get the definitions.

  The hubless entry basically is present and set only if there
  is no hub.  In this case the hub_type entry is not present.

  The partition_id entry contains the partition id.
  UV systems can be partitioned into multiple physical
  machines, which each partition running a unique copy
  of the operating system. Each partition will have a unique
  partition id.

  The coherence_id entry contains the coherence id.
  A partitioned UV system can have one or more coherence
  domains. The coherence id indicates which coherence domain
  this partition is in.

  The uv_type entry contains the hub revision number.
  This value can be used to identify the UV system version::

   "0.*" = Hubless UV ('*' is subtype)
   "3.0" = UV2
   "5.0" = UV3
   "7.0" = UV4
   "7.1" = UV4a
   "9.0" = UV5

  The /sys/firmware/sgi_uv directory also contains two directories::

   hubs/
   pcibuses/

  The hubs directory contains a number of hub objects, each representing
  a UV Hub visible to the BIOS. Each hub object's name is appended by a
  unique ordinal value (ex. /sys/firmware/sgi_uv/hubs/hub_5)

  Each hub object directory contains a number of read-only attributes::

   cnode
   location
   name
   nasid
   shared
   this_partition

  The cnode entry contains the cnode number of the corresponding hub.
  If a cnode value is not applicable, the value returned will be -1.

  The location entry contains the location string of the corresponding hub.
  This value is used to physically identify a hub within a system.

  The name entry contains the name of the corresponding hub. This name can
  be two variants::

   "UVHub x.x" = A 'node' ASIC, connecting a CPU to the interconnect
   fabric. The 'x.x' value represents the ASIC revision.
   (ex. 'UVHub 5.0')

   "NLxRouter" = A 'router ASIC, only connecting other ASICs to
   the interconnect fabric. The 'x' value representing
   the fabric technology version. (ex. 'NL8Router')

  The nasid entry contains the nasid number of the corresponding hub.
  If a nasid value is not applicable, the value returned will be -1.

  The shared entry contains a boolean value describing whether the
  corresponding hub is shared between system partitions.

  The this_partition entry contains a boolean value describing whether
  the corresponding hub is local to the current partition.

  Each hub object directory also contains a number of port objects,
  each representing a fabric port on the corresponding hub.
  A port object's name is appended by a unique ordinal value
  (ex. /sys/firmware/sgi_uv/hubs/hub_5/port_3)

  Each port object directory contains a number of read-only attributes::

   conn_hub
   conn_port

  The conn_hub entry contains a value representing the unique
  ordinal value of the hub on the other end of the fabric
  cable plugged into the port. If the port is disconnected,
  the value returned will be -1.

  The conn_port entry contains a value representing the unique
  ordinal value of the port on the other end of the fabric cable
  plugged into the port. If the port is disconnected, the value
  returned will be -1.

  Ex:
   A value of '3' is read from:
    /sys/firmware/sgi_uv/hubs/hub_5/port_3/conn_hub

   and a value of '6' is read from:
    /sys/firmware/sgi_uv/hubs/hub_5/port_3/conn_port

   representing that this port is connected to:
    /sys/firmware/sgi_uv/hubs/hub_3/port_6

  The pcibuses directory contains a number of PCI bus objects.
  Each PCI bus object's name is appended by its PCI bus address.
  (ex. pcibus_0003:80)

  Each pcibus object has a number of possible read-only attributes::

   type
   location
   slot
   ppb_addr
   iio_stack

  The type entry contains a value describing the type of IO at
  the corresponding PCI bus address. Known possible values
  across all UV versions are::

   BASE IO
   PCIe IO
   PCIe SLOT
   NODE IO
   Riser
   PPB

  The location entry contains the location string of the UV Hub
  of the CPU physically connected to the corresponding PCI bus.

  The slot entry contains the physical slot number of the
  corresponding PCI bus. This value is used to physically locate
  PCI cards within a system.

  The ppb_addr entry contains the PCI address string of the
  bridged PCI bus. This entry is only present when the PCI bus
  object type is 'PPB'.

  The iio_stack entry contains a value describing the IIO stack
  number that the corresponding PCI bus object is connected to.

¤ Dauer der Verarbeitung: 0.1 Sekunden  (vorverarbeitet)  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.






                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge