Kernel driver lm73
==================

Supported chips:

  * Texas Instruments LM73

    Prefix: 'lm73'

    Addresses scanned: I2C 0x48, 0x49, 0x4a, 0x4c, 0x4d, and 0x4e

    Datasheet: Publicly available at the Texas Instruments website

        https://www.ti.com/product/lm73


Author: Guillaume Ligneul <guillaume.ligneul@gmail.com>

Documentation: Chris Verges <kg4ysn@gmail.com>


Description
-----------

The LM73 is a digital temperature sensor.  All temperature values are
given in degrees Celsius.

Measurement Resolution Support
------------------------------

The LM73 supports four resolutions, defined in terms of degrees C per
LSB: 0.25, 0.125, 0.0625, and 0.3125.  Changing the resolution mode
affects the conversion time of the LM73's analog-to-digital converter.
From userspace, the desired resolution can be specified as a function of
conversion time via the 'update_interval' sysfs attribute for the
device.  This attribute will normalize ranges of input values to the
maximum times defined for the resolution in the datasheet.

    ============= ============= ============
    Resolution    Conv. Time    Input Range
    (C/LSB)       (msec)        (msec)
    ============= ============= ============
    0.25          14             0..14
    0.125         28            15..28
    0.0625        56            29..56
    0.03125       112           57..infinity
    ============= ============= ============

The following examples show how the 'update_interval' attribute can be
used to change the conversion time::

    $ echo 0 > update_interval
    $ cat update_interval
    14
    $ cat temp1_input
    24250

    $ echo 22 > update_interval
    $ cat update_interval
    28
    $ cat temp1_input
    24125

    $ echo 56 > update_interval
    $ cat update_interval
    56
    $ cat temp1_input
    24062

    $ echo 85 > update_interval
    $ cat update_interval
    112
    $ cat temp1_input
    24031

As shown here, the lm73 driver automatically adjusts any user input for
'update_interval' via a step function.  Reading back the
'update_interval' value after a write operation will confirm the
conversion time actively in use.

Mathematically, the resolution can be derived from the conversion time
via the following function:

   g(x) = 0.250 * [log(x/14) / log(2)]

where 'x' is the output from 'update_interval' and 'g(x)' is the
resolution in degrees C per LSB.

Alarm Support
-------------

The LM73 features a simple over-temperature alarm mechanism.  This
feature is exposed via the sysfs attributes.

The attributes 'temp1_max_alarm' and 'temp1_min_alarm' are flags
provided by the LM73 that indicate whether the measured temperature has
passed the 'temp1_max' and 'temp1_min' thresholds, respectively.  These
values _must_ be read to clear the registers on the LM73.

[ Dauer der Verarbeitung: 0.3 Sekunden  (vorverarbeitet)  ]

                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....
    

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge