Anforderungen  |   Konzepte  |   Entwurf  |   Entwicklung  |   Qualitätssicherung  |   Lebenszyklus  |   Steuerung
 
 
 
 


Quelle  pli1209bc.rst   Sprache: unbekannt

 
.. SPDX-License-Identifier: GPL-2.0

Kernel driver pli1209bc
=======================

Supported chips:

  * Digital Supervisor PLI1209BC

    Prefix: 'pli1209bc'

    Addresses scanned: 0x50 - 0x5F

    Datasheet: https://www.vicorpower.com/documents/datasheets/ds-PLI1209BCxyzz-VICOR.pdf

Authors:
    - Marcello Sylvester Bauer <sylv@sylv.io>

Description
-----------

The Vicor PLI1209BC is an isolated digital power system supervisor that provides
a communication interface between a host processor and one Bus Converter Module
(BCM). The PLI communicates with a system controller via a PMBus compatible
interface over an isolated UART interface. Through the PLI, the host processor
can configure, set protection limits, and monitor the BCM.

Sysfs entries
-------------

======================= ========================================================
in1_label  "vin2"
in1_input  Input voltage.
in1_rated_min  Minimum rated input voltage.
in1_rated_max  Maximum rated input voltage.
in1_max   Maximum input voltage.
in1_max_alarm  Input voltage high alarm.
in1_crit  Critical input voltage.
in1_crit_alarm  Input voltage critical alarm.

in2_label  "vout2"
in2_input  Output voltage.
in2_rated_min  Minimum rated output voltage.
in2_rated_max  Maximum rated output voltage.
in2_alarm  Output voltage alarm

curr1_label  "iin2"
curr1_input  Input current.
curr1_max  Maximum input current.
curr1_max_alarm  Maximum input current high alarm.
curr1_crit  Critical input current.
curr1_crit_alarm Input current critical alarm.

curr2_label  "iout2"
curr2_input  Output current.
curr2_crit  Critical output current.
curr2_crit_alarm Output current critical alarm.
curr2_max  Maximum output current.
curr2_max_alarm  Output current high alarm.

power1_label  "pin2"
power1_input  Input power.
power1_alarm  Input power alarm.

power2_label  "pout2"
power2_input  Output power.
power2_rated_max Maximum rated output power.

temp1_input  Die temperature.
temp1_alarm  Die temperature alarm.
temp1_max  Maximum die temperature.
temp1_max_alarm  Die temperature high alarm.
temp1_crit  Critical die temperature.
temp1_crit_alarm Die temperature critical alarm.
======================= ========================================================

[ Dauer der Verarbeitung: 0.2 Sekunden  (vorverarbeitet)  ]

                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....
    

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge