Anforderungen  |   Konzepte  |   Entwurf  |   Entwicklung  |   Qualitätssicherung  |   Lebenszyklus  |   Steuerung
 
 
 
 


Quelle  powerpc-hcalls.py   Sprache: Python

 
# SPDX-License-Identifier: GPL-2.0+
#
# Copyright (C) 2018 Ravi Bangoria, IBM Corporation
#
# Hypervisor call statisics

from __future__ import print_function

import os
import sys

sys.path.append(os.environ['PERF_EXEC_PATH'] + \
 '/scripts/python/Perf-Trace-Util/lib/Perf/Trace')

from perf_trace_context import *
from Core import *
from Util import *

# output: {
# opcode: {
# 'min': minimum time nsec
# 'max': maximum time nsec
# 'time': average time nsec
# 'cnt': counter
# } ...
# }
output = {}

# d_enter: {
# cpu: {
# opcode: nsec
# } ...
# }
d_enter = {}

hcall_table = {
 4: 'H_REMOVE',
 8: 'H_ENTER',
 12: 'H_READ',
 16: 'H_CLEAR_MOD',
 20: 'H_CLEAR_REF',
 24: 'H_PROTECT',
 28: 'H_GET_TCE',
 32: 'H_PUT_TCE',
 36: 'H_SET_SPRG0',
 40: 'H_SET_DABR',
 44: 'H_PAGE_INIT',
 48: 'H_SET_ASR',
 52: 'H_ASR_ON',
 56: 'H_ASR_OFF',
 60: 'H_LOGICAL_CI_LOAD',
 64: 'H_LOGICAL_CI_STORE',
 68: 'H_LOGICAL_CACHE_LOAD',
 72: 'H_LOGICAL_CACHE_STORE',
 76: 'H_LOGICAL_ICBI',
 80: 'H_LOGICAL_DCBF',
 84: 'H_GET_TERM_CHAR',
 88: 'H_PUT_TERM_CHAR',
 92: 'H_REAL_TO_LOGICAL',
 96: 'H_HYPERVISOR_DATA',
 100: 'H_EOI',
 104: 'H_CPPR',
 108: 'H_IPI',
 112: 'H_IPOLL',
 116: 'H_XIRR',
 120: 'H_MIGRATE_DMA',
 124: 'H_PERFMON',
 220: 'H_REGISTER_VPA',
 224: 'H_CEDE',
 228: 'H_CONFER',
 232: 'H_PROD',
 236: 'H_GET_PPP',
 240: 'H_SET_PPP',
 244: 'H_PURR',
 248: 'H_PIC',
 252: 'H_REG_CRQ',
 256: 'H_FREE_CRQ',
 260: 'H_VIO_SIGNAL',
 264: 'H_SEND_CRQ',
 272: 'H_COPY_RDMA',
 276: 'H_REGISTER_LOGICAL_LAN',
 280: 'H_FREE_LOGICAL_LAN',
 284: 'H_ADD_LOGICAL_LAN_BUFFER',
 288: 'H_SEND_LOGICAL_LAN',
 292: 'H_BULK_REMOVE',
 304: 'H_MULTICAST_CTRL',
 308: 'H_SET_XDABR',
 312: 'H_STUFF_TCE',
 316: 'H_PUT_TCE_INDIRECT',
 332: 'H_CHANGE_LOGICAL_LAN_MAC',
 336: 'H_VTERM_PARTNER_INFO',
 340: 'H_REGISTER_VTERM',
 344: 'H_FREE_VTERM',
 348: 'H_RESET_EVENTS',
 352: 'H_ALLOC_RESOURCE',
 356: 'H_FREE_RESOURCE',
 360: 'H_MODIFY_QP',
 364: 'H_QUERY_QP',
 368: 'H_REREGISTER_PMR',
 372: 'H_REGISTER_SMR',
 376: 'H_QUERY_MR',
 380: 'H_QUERY_MW',
 384: 'H_QUERY_HCA',
 388: 'H_QUERY_PORT',
 392: 'H_MODIFY_PORT',
 396: 'H_DEFINE_AQP1',
 400: 'H_GET_TRACE_BUFFER',
 404: 'H_DEFINE_AQP0',
 408: 'H_RESIZE_MR',
 412: 'H_ATTACH_MCQP',
 416: 'H_DETACH_MCQP',
 420: 'H_CREATE_RPT',
 424: 'H_REMOVE_RPT',
 428: 'H_REGISTER_RPAGES',
 432: 'H_DISABLE_AND_GETC',
 436: 'H_ERROR_DATA',
 440: 'H_GET_HCA_INFO',
 444: 'H_GET_PERF_COUNT',
 448: 'H_MANAGE_TRACE',
 468: 'H_FREE_LOGICAL_LAN_BUFFER',
 472: 'H_POLL_PENDING',
 484: 'H_QUERY_INT_STATE',
 580: 'H_ILLAN_ATTRIBUTES',
 592: 'H_MODIFY_HEA_QP',
 596: 'H_QUERY_HEA_QP',
 600: 'H_QUERY_HEA',
 604: 'H_QUERY_HEA_PORT',
 608: 'H_MODIFY_HEA_PORT',
 612: 'H_REG_BCMC',
 616: 'H_DEREG_BCMC',
 620: 'H_REGISTER_HEA_RPAGES',
 624: 'H_DISABLE_AND_GET_HEA',
 628: 'H_GET_HEA_INFO',
 632: 'H_ALLOC_HEA_RESOURCE',
 644: 'H_ADD_CONN',
 648: 'H_DEL_CONN',
 664: 'H_JOIN',
 676: 'H_VASI_STATE',
 688: 'H_ENABLE_CRQ',
 696: 'H_GET_EM_PARMS',
 720: 'H_SET_MPP',
 724: 'H_GET_MPP',
 748: 'H_HOME_NODE_ASSOCIATIVITY',
 756: 'H_BEST_ENERGY',
 764: 'H_XIRR_X',
 768: 'H_RANDOM',
 772: 'H_COP',
 788: 'H_GET_MPP_X',
 796: 'H_SET_MODE',
 61440: 'H_RTAS',
}

def hcall_table_lookup(opcode):
 if (opcode in hcall_table):
  return hcall_table[opcode]
 else:
  return opcode

print_ptrn = '%-28s%10s%10s%10s%10s'

def trace_end():
 print(print_ptrn % ('hcall''count''min(ns)''max(ns)''avg(ns)'))
 print('-' * 68)
 for opcode in output:
  h_name = hcall_table_lookup(opcode)
  time = output[opcode]['time']
  cnt = output[opcode]['cnt']
  min_t = output[opcode]['min']
  max_t = output[opcode]['max']

  print(print_ptrn % (h_name, cnt, min_t, max_t, time//cnt))

def powerpc__hcall_exit(name, context, cpu, sec, nsec, pid, comm, callchain,
   opcode, retval):
 if (cpu in d_enter and opcode in d_enter[cpu]):
  diff = nsecs(sec, nsec) - d_enter[cpu][opcode]

  if (opcode in output):
   output[opcode]['time'] += diff
   output[opcode]['cnt'] += 1
   if (output[opcode]['min'] > diff):
    output[opcode]['min'] = diff
   if (output[opcode]['max'] < diff):
    output[opcode]['max'] = diff
  else:
   output[opcode] = {
    'time': diff,
    'cnt': 1,
    'min': diff,
    'max': diff,
   }

  del d_enter[cpu][opcode]
# else:
# print("Can't find matching hcall_enter event. Ignoring sample")

def powerpc__hcall_entry(event_name, context, cpu, sec, nsec, pid, comm,
    callchain, opcode):
  if (cpu in d_enter):
   d_enter[cpu][opcode] = nsecs(sec, nsec)
  else:
   d_enter[cpu] = {opcode: nsecs(sec, nsec)}

Messung V0.5
C=91 H=95 G=92

¤ Dauer der Verarbeitung: 0.10 Sekunden  (vorverarbeitet)  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.






                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge