Anforderungen  |   Konzepte  |   Entwurf  |   Entwicklung  |   Qualitätssicherung  |   Lebenszyklus  |   Steuerung
 
 
 
 


Quelle  clone3_clear_sighand.c   Sprache: C

 
/* SPDX-License-Identifier: GPL-2.0 */

#define _GNU_SOURCE
#include <errno.h>
#include <sched.h>
#include <signal.h>
#include <stdio.h>
#include <stdlib.h>
#include <string.h>
#include <unistd.h>
#include <linux/sched.h>
#include <linux/types.h>
#include <sys/syscall.h>
#include <sys/wait.h>

#include "../kselftest.h"
#include "clone3_selftests.h"

static void nop_handler(int signo)
{
}

static int wait_for_pid(pid_t pid)
{
 int status, ret;

again:
 ret = waitpid(pid, &status, 0);
 if (ret == -1) {
  if (errno == EINTR)
   goto again;

  return -1;
 }

 if (!WIFEXITED(status))
  return -1;

 return WEXITSTATUS(status);
}

static void test_clone3_clear_sighand(void)
{
 int ret;
 pid_t pid;
 struct __clone_args args = {};
 struct sigaction act;

 /*
 * Check that CLONE_CLEAR_SIGHAND and CLONE_SIGHAND are mutually
 * exclusive.
 */

 args.flags |= CLONE_CLEAR_SIGHAND | CLONE_SIGHAND;
 args.exit_signal = SIGCHLD;
 pid = sys_clone3(&args, sizeof(args));
 if (pid > 0)
  ksft_exit_fail_msg(
   "clone3(CLONE_CLEAR_SIGHAND | CLONE_SIGHAND) succeeded\n");

 act.sa_handler = nop_handler;
 ret = sigemptyset(&act.sa_mask);
 if (ret < 0)
  ksft_exit_fail_msg("%s - sigemptyset() failed\n",
       strerror(errno));

 act.sa_flags = 0;

 /* Register signal handler for SIGUSR1 */
 ret = sigaction(SIGUSR1, &act, NULL);
 if (ret < 0)
  ksft_exit_fail_msg(
   "%s - sigaction(SIGUSR1, &act, NULL) failed\n",
   strerror(errno));

 /* Register signal handler for SIGUSR2 */
 ret = sigaction(SIGUSR2, &act, NULL);
 if (ret < 0)
  ksft_exit_fail_msg(
   "%s - sigaction(SIGUSR2, &act, NULL) failed\n",
   strerror(errno));

 /* Check that CLONE_CLEAR_SIGHAND works. */
 args.flags = CLONE_CLEAR_SIGHAND;
 pid = sys_clone3(&args, sizeof(args));
 if (pid < 0)
  ksft_exit_fail_msg("%s - clone3(CLONE_CLEAR_SIGHAND) failed\n",
       strerror(errno));

 if (pid == 0) {
  ret = sigaction(SIGUSR1, NULL, &act);
  if (ret < 0)
   exit(EXIT_FAILURE);

  if (act.sa_handler != SIG_DFL)
   exit(EXIT_FAILURE);

  ret = sigaction(SIGUSR2, NULL, &act);
  if (ret < 0)
   exit(EXIT_FAILURE);

  if (act.sa_handler != SIG_DFL)
   exit(EXIT_FAILURE);

  exit(EXIT_SUCCESS);
 }

 ret = wait_for_pid(pid);
 if (ret)
  ksft_exit_fail_msg(
   "Failed to clear signal handler for child process\n");

 ksft_test_result_pass("Cleared signal handlers for child process\n");
}

int main(int argc, char **argv)
{
 ksft_print_header();
 ksft_set_plan(1);
 test_clone3_supported();

 test_clone3_clear_sighand();

 ksft_exit_pass();
}

Messung V0.5
C=94 H=95 G=94

¤ Dauer der Verarbeitung: 0.9 Sekunden  (vorverarbeitet)  ¤

*© Formatika GbR, Deutschland






Wurzel

Suchen

Beweissystem der NASA

Beweissystem Isabelle

NIST Cobol Testsuite

Cephes Mathematical Library

Wiener Entwicklungsmethode

Haftungshinweis

Die Informationen auf dieser Webseite wurden nach bestem Wissen sorgfältig zusammengestellt. Es wird jedoch weder Vollständigkeit, noch Richtigkeit, noch Qualität der bereit gestellten Informationen zugesichert.

Bemerkung:

Die farbliche Syntaxdarstellung und die Messung sind noch experimentell.






                                                                                                                                                                                                                                                                                                                                                                                                     


Neuigkeiten

     Aktuelles
     Motto des Tages

Software

     Produkte
     Quellcodebibliothek

Aktivitäten

     Artikel über Sicherheit
     Anleitung zur Aktivierung von SSL

Muße

     Gedichte
     Musik
     Bilder

Jenseits des Üblichen ....
    

Besucherstatistik

Besucherstatistik

Monitoring

Montastic status badge