#!/bin/env python3
# SPDX-License-Identifier: GPL-2.0
import subprocess
from shutil import which
from os import pread
# CDLL calls dlopen underneath.
# Calling it with None (null), we get handle to the our own image (python interpreter).
# We hope to find sched_getcpu() inside ;]
# This is a bit ugly, but helps shipping working software, so..
try :
import ctypes
this_image = ctypes.CDLL(None )
BASE_CPU = this_image.sched_getcpu()
except :
BASE_CPU = 0 # If we fail, set to 0 and pray it's not offline.
MSR_IA32_MPERF = 0x000000e7
MSR_IA32_APERF = 0x000000e8
def check_perf_access():
perf = which('perf' )
if perf is None :
print('SKIP: Could not find perf binary, thus could not determine perf access.' )
return False
def has_perf_counter_access(counter_name):
proc_perf = subprocess.run([perf, 'stat' , '-e' , counter_name, '--timeout' , '10' ],
capture_output = True )
if proc_perf.returncode != 0:
print(f'SKIP: Could not read {counter_name} perf counter, assuming no access.' )
return False
if b'' in proc_perf.stderr:
print(f'SKIP: Could not read {counter_name} perf counter, assuming no access.' )
return False
return True
if not has_perf_counter_access('msr/mperf/' ):
return False
if not has_perf_counter_access('msr/aperf/' ):
return False
if not has_perf_counter_access('msr/smi/' ):
return False
return True
def check_msr_access():
try :
file_msr = open(f'/dev/cpu/{BASE_CPU}/msr' , 'rb' )
except :
return False
if len(pread(file_msr.fileno(), 8, MSR_IA32_MPERF)) != 8:
return False
if len(pread(file_msr.fileno(), 8, MSR_IA32_APERF)) != 8:
return False
return True
has_perf_access = check_perf_access()
has_msr_access = check_msr_access()
turbostat_counter_source_opts = ['' ]
if has_msr_access:
turbostat_counter_source_opts.append('--no-perf' )
else :
print('SKIP: doesn\' t have MSR access, skipping run with --no-perf')
if has_perf_access:
turbostat_counter_source_opts.append('--no-msr' )
else :
print('SKIP: doesn\' t have perf access, skipping run with --no-msr')
if not has_msr_access and not has_perf_access:
print('SKIP: No MSR nor perf access detected. Skipping the tests entirely' )
exit(0)
turbostat = which('turbostat' )
if turbostat is None :
print('Could not find turbostat binary' )
exit(1)
timeout = which('timeout' )
if timeout is None :
print('Could not find timeout binary' )
exit(1)
proc_turbostat = subprocess.run([turbostat, '--list' ], capture_output = True )
if proc_turbostat.returncode != 0:
print(f'turbostat failed with {proc_turbostat.returncode}' )
exit(1)
EXPECTED_COLUMNS_DEBUG_DEFAULT = b'usec\tTime_Of_Day_Seconds\tAPIC\tX2APIC'
SMI_APERF_MPERF_DEPENDENT_BICS = [
'SMI' ,
'Avg_MHz' ,
'Busy%' ,
'Bzy_MHz' ,
]
if has_perf_access:
SMI_APERF_MPERF_DEPENDENT_BICS.append('IPC' )
for bic in SMI_APERF_MPERF_DEPENDENT_BICS:
for counter_source_opt in turbostat_counter_source_opts:
# Ugly special case, but it is what it is..
if counter_source_opt == '--no-perf' and bic == 'IPC' :
continue
expected_columns = bic.encode()
expected_columns_debug = EXPECTED_COLUMNS_DEBUG_DEFAULT + f'\t{bic}' .encode()
#
# Run turbostat for some time and send SIGINT
#
timeout_argv = [timeout, '--preserve-status' , '-s' , 'SIGINT' , '-k' , '3' , '0.2s' ]
turbostat_argv = [turbostat, '-i' , '0.50' , '--show' , bic]
if counter_source_opt:
turbostat_argv.append(counter_source_opt)
print(f'Running turbostat with {turbostat_argv=}... ' , end = '' , flush = True )
proc_turbostat = subprocess.run(timeout_argv + turbostat_argv, capture_output = True )
if proc_turbostat.returncode != 0:
print(f'turbostat failed with {proc_turbostat.returncode}' )
exit(1)
actual_columns = proc_turbostat.stdout.split(b'\n' )[0]
if expected_columns != actual_columns:
print(f'turbostat column check failed\n{expected_columns=}\n{actual_columns=}' )
exit(1)
print('OK' )
#
# Same, but with --debug
#
turbostat_argv.append('--debug' )
print(f'Running turbostat with {turbostat_argv=}... ' , end = '' , flush = True )
proc_turbostat = subprocess.run(timeout_argv + turbostat_argv, capture_output = True )
if proc_turbostat.returncode != 0:
print(f'turbostat failed with {proc_turbostat.returncode}' )
exit(1)
actual_columns = proc_turbostat.stdout.split(b'\n' )[0]
if expected_columns_debug != actual_columns:
print(f'turbostat column check failed\n{expected_columns_debug=}\n{actual_columns=}' )
exit(1)
print('OK' )
Messung V0.5 C=92 H=97 G=94
¤ Dauer der Verarbeitung: 0.3 Sekunden
¤
*© Formatika GbR, Deutschland